Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,043

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UM0434 # 04 Y:2013 04 2013 OPTIMIZE PLANT POWER FACTOR $3,479 $4,000 Not Implemented
UM0434 # 05 Y:2013 05 2013 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,445 $8,750 Not Implemented
UM0434 # 06 Y:2013 06 2013 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,318 $2,500 Implemented
UM0434 # 07 Y:2013 07 2013 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,027 $200 Not Implemented
DL0115 # 01 Y:2013 01 2013 TURN OFF EQUIPMENT WHEN NOT IN USE $3,106 $0 Implemented
DL0115 # 02 Y:2013 02 2013 VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE $2,900 $350 Implemented
DL0115 # 03 Y:2013 03 2013 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $2,400 $16,000 Not Implemented
DL0115 # 04 Y:2013 04 2013 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $4,460 $29,700 Implemented
DL0115 # 05 Y:2013 05 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,140 $3,380 Not Implemented
DL0115 # 06 Y:2013 06 2013 INSTALL OCCUPANCY SENSORS $640 $600 Implemented
DL0115 # 07 Y:2013 07 2013 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $830 $6,000 Not Implemented
DL0115 # 08 Y:2013 08 2013 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $1,405 $2,110 Not Implemented
DL0115 # 09 Y:2013 09 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,710 $8,485 Implemented
DL0115 # 10 Y:2013 10 2013 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $2,270 $0 Implemented
MA0717 # 01 Y:2013 01 2013 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $21,124 $14,700 Not Implemented
MA0717 # 02 Y:2013 02 2013 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $12,293 $8,275 Implemented
MA0717 # 03 Y:2013 03 2013 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $3,036 $8,700 Not Implemented
MA0717 # 04 Y:2013 04 2013 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,986 $5,700 Implemented
MA0717 # 05 Y:2013 05 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,679 $4,082 Implemented
MZ0134 # 01 Y:2013 01 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $53,250 $61,965 Implemented
MZ0134 # 02 Y:2013 02 2013 INSTALL OCCUPANCY SENSORS $22,321 $12,640 Not Implemented
MZ0134 # 03 Y:2013 03 2013 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $10,044 $2,500 Implemented
MZ0134 # 04 Y:2013 04 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,322 $1,333 Not Implemented
MZ0134 # 05 Y:2013 05 2013 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $5,688 $16,575 Not Implemented
MZ0134 # 06 Y:2013 06 2013 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $4,932 $2,000 Not Implemented