Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,377
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0040 # 08 Y:1985 | 08 | 1985 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,801 | $1,500 | Not Implemented |
CO0040 # 09 Y:1985 | 09 | 1985 | INSTALL / REPAIR INSULATION ON STEAM LINES | $555 | $700 | Implemented |
CO0040 # 10 Y:1985 | 10 | 1985 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,094 | $5,000 | Not Implemented |
CO0040 # 11 Y:1985 | 11 | 1985 | INCREASE AMOUNT OF CONDENSATE RETURNED | $3,959 | $9,000 | Implemented |
CO0040 # 12 Y:1985 | 12 | 1985 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $7,066 | $1,000 | Implemented |
CO0041 # 01 Y:1985 | 01 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $460 | $80 | Implemented |
CO0041 # 02 Y:1985 | 02 | 1985 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $359 | $2,000 | Not Implemented |
CO0041 # 03 Y:1985 | 03 | 1985 | TURN OFF EQUIPMENT WHEN NOT IN USE | $125 | $200 | Implemented |
CO0041 # 04 Y:1985 | 04 | 1985 | INCREASE AMOUNT OF CONDENSATE RETURNED | $139 | $180 | Implemented |
CO0041 # 05 Y:1985 | 05 | 1985 | AIR CONDITION ONLY SPACE NECESSARY | $1,164 | $2,000 | Implemented |
CO0041 # 06 Y:1985 | 06 | 1985 | INSTALL / REPAIR INSULATION ON STEAM LINES | $838 | $95 | Implemented |
CO0041 # 07 Y:1985 | 07 | 1985 | AIR CONDITION ONLY SPACE NECESSARY | $2,136 | $225 | Implemented |
CO0041 # 08 Y:1985 | 08 | 1985 | AIR CONDITION ONLY SPACE NECESSARY | $3,403 | $84 | Not Implemented |
CO0041 # 09 Y:1985 | 09 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $599 | $400 | Implemented |
CO0041 # 10 Y:1985 | 10 | 1985 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $206 | $258 | Not Implemented |
CO0041 # 11 Y:1985 | 11 | 1985 | USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC | $924 | $5,000 | Not Implemented |
CO0041 # 12 Y:1985 | 12 | 1985 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,701 | $0 | Implemented |
CO0041 # 13 Y:1985 | 13 | 1985 | REDESIGN PROCESS | $1,481 | $1,140 | Not Implemented |
CO0041 # 14 Y:1985 | 14 | 1985 | IMPROVE LUBRICATION PRACTICES | $882 | $100 | Not Implemented |
CO0042 # 01 Y:1985 | 01 | 1985 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $5,853 | $645 | Implemented |
CO0042 # 02 Y:1985 | 02 | 1985 | TURN OFF EQUIPMENT WHEN NOT IN USE | $6,858 | $450 | Not Implemented |
CO0042 # 03 Y:1985 | 03 | 1985 | TURN OFF EQUIPMENT WHEN NOT IN USE | $91 | $100 | Not Implemented |
CO0042 # 04 Y:1985 | 04 | 1985 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,923 | $600 | Not Implemented |
CO0042 # 05 Y:1985 | 05 | 1985 | RECOVER WASTE HEAT FROM EQUIPMENT | $283 | $200 | Implemented |
CO0042 # 06 Y:1985 | 06 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $69 | $100 | Not Implemented |