Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,754
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0073 # 09 Y:1983 | 09 | 1983 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,659 | $490 | Not Implemented |
OK0073 # 10 Y:1983 | 10 | 1983 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,063 | $270 | Not Implemented |
OK0073 # 11 Y:1983 | 11 | 1983 | HEAT WATER WITH EXHAUST HEAT | $54,540 | $36,000 | Implemented |
OK0073 # 12 Y:1983 | 12 | 1983 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $6,511 | $27,000 | Not Implemented |
OK0073 # 13 Y:1983 | 13 | 1983 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $471 | $477 | Not Implemented |
OK0073 # 14 Y:1983 | 14 | 1983 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $79 | $136 | Not Implemented |
OK0064 # 01 Y:1982 | 01 | 1982 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $707 | $56 | Implemented |
OK0064 # 02 Y:1982 | 02 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $1,830 | $400 | Implemented |
OK0064 # 03 Y:1982 | 03 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,330 | $1,405 | Implemented |
OK0064 # 04 Y:1982 | 04 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $1,749 | $560 | Implemented |
OK0064 # 05 Y:1982 | 05 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $485 | $0 | Implemented |
OK0064 # 06 Y:1982 | 06 | 1982 | DE-ENERGIZE EXCESS TRANSFORMER CAPACITY | $586 | $0 | Implemented |
OK0066 # 01 Y:1982 | 01 | 1982 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,410 | $9,010 | Not Implemented |
OK0066 # 02 Y:1982 | 02 | 1982 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $973 | $633 | Implemented |
OK0066 # 03 Y:1982 | 03 | 1982 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $718 | $433 | Not Implemented |
OK0066 # 04 Y:1982 | 04 | 1982 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,042 | $0 | Not Implemented |
OK0066 # 05 Y:1982 | 05 | 1982 | OPTIMIZE PLANT POWER FACTOR | $1,504 | $1,520 | Not Implemented |
OK0066 # 06 Y:1982 | 06 | 1982 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $56 | $114 | Not Implemented |
OK0066 # 07 Y:1982 | 07 | 1982 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $5,173 | $24,000 | Not Implemented |
OK0066 # 08 Y:1982 | 08 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $69 | $296 | Implemented |
OK0066 # 09 Y:1982 | 09 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $263 | $95 | Not Implemented |
OK0066 # 10 Y:1982 | 10 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $36 | $38 | Not Implemented |
OK0067 # 01 Y:1982 | 01 | 1982 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $13,100 | $40,311 | Not Implemented |
OK0067 # 02 Y:1982 | 02 | 1982 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $63,919 | $3,400 | Implemented |
OK0067 # 03 Y:1982 | 03 | 1982 | INSULATE BARE EQUIPMENT | $5,689 | $2,430 | Implemented |