ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0048 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $398 | $265 | Not Implemented |
OK0048 # 02 Y:1982 | 02 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $126 | $738 | Not Implemented |
OK0048 # 03 Y:1982 | 03 | 1982 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $35 | $17 | Implemented |
OK0048 # 04 Y:1982 | 04 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $1,338 | $400 | Not Implemented |
OK0051 # 01 Y:1982 | 01 | 1982 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,367 | $200 | Implemented |
OK0051 # 02 Y:1982 | 02 | 1982 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,675 | $3,000 | Implemented |
OK0051 # 03 Y:1982 | 03 | 1982 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $13,620 | $8,300 | Not Implemented |
OK0051 # 04 Y:1982 | 04 | 1982 | OPTIMIZE PLANT POWER FACTOR | $5,976 | $3,900 | Not Implemented |
OK0051 # 05 Y:1982 | 05 | 1982 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $130 | $0 | Implemented |
OK0051 # 06 Y:1982 | 06 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $29 | $13 | Implemented |
OK0051 # 07 Y:1982 | 07 | 1982 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,612 | $12,150 | Implemented |
OK0055 # 01 Y:1982 | 01 | 1982 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,052 | $58 | Not Implemented |
OK0055 # 02 Y:1982 | 02 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $3,457 | $800 | Not Implemented |
OK0055 # 03 Y:1982 | 03 | 1982 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $2,901 | $4,000 | Not Implemented |
OK0055 # 04 Y:1982 | 04 | 1982 | REDUCE GLAZED AREAS IN BUILDINGS | $2,354 | $3,036 | Not Implemented |
OK0037 # 01 Y:1982 | 01 | 1982 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,854 | $300 | Not Implemented |
OK0037 # 02 Y:1982 | 02 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $1,647 | $552 | Not Implemented |
OK0037 # 03 Y:1982 | 03 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $749 | $1,484 | Not Implemented |
OK0037 # 04 Y:1982 | 04 | 1982 | REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY | $43 | $125 | Not Implemented |
OK0038 # 01 Y:1982 | 01 | 1982 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $217 | $313 | Not Implemented |
OK0038 # 02 Y:1982 | 02 | 1982 | USE RADIANT HEATER FOR SPOT HEATING | $23,027 | $29,970 | Not Implemented |
OK0038 # 03 Y:1982 | 03 | 1982 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $259 | $165 | Not Implemented |
OK0038 # 04 Y:1982 | 04 | 1982 | INSTALL STORM WINDOWS AND DOORS | $4,750 | $17,358 | Not Implemented |
OK0040 # 01 Y:1982 | 01 | 1982 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $3,020 | $2,680 | Implemented |
OK0040 # 02 Y:1982 | 02 | 1982 | PLANT TREES OR SHRUBS NEAR WINDOWS TO SHIELD FROM SUNLIGHT | $1,682 | $4,000 | Implemented |