Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
6,055
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UL0116 # 06 Y:1995 | 06 | 1995 | RECYCLE WASTE INK AND CLEANUP SOLVENT | $15,551 | $7,335 | Implemented |
UL0116 # 07 Y:1995 | 07 | 1995 | RECYCLE WASTE INK AND CLEANUP SOLVENT | $13,800 | $0 | Implemented |
UL0116 # 08 Y:1995 | 08 | 1995 | SELL USED PLATES TO AN ALUMINUM RECYCLER | $496 | $75 | Not Implemented |
UL0116 # 09 Y:1995 | 09 | 1995 | COVER CONTAINERS TO MINIMIZE EVAPORATIVE LOSSES | $342 | $0 | Not Implemented |
UL0116 # 10 Y:1995 | 10 | 1995 | USE A DIFFERENT OR RECYCLED RAW MATERIAL | $12,585 | $0 | Not Implemented |
BD0020 # 01 Y:1995 | 01 | 1995 | OPTIMIZE PLANT POWER FACTOR | $30,091 | $52,250 | Implemented |
BD0020 # 02 Y:1995 | 02 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,313 | $10,254 | Not Implemented |
BD0020 # 03 Y:1995 | 03 | 1995 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $6,172 | $7,470 | Not Implemented |
BD0020 # 04 Y:1995 | 04 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,662 | $9,150 | Not Implemented |
TN0540 # 01 Y:1995 | 01 | 1995 | INSTALL / REPAIR INSULATION ON STEAM LINES | $5,373 | $2,280 | Implemented |
TN0540 # 02 Y:1995 | 02 | 1995 | INSULATE BARE EQUIPMENT | $4,639 | $2,070 | Not Implemented |
TN0540 # 03 Y:1995 | 03 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $15,295 | $17,920 | Not Implemented |
TN0540 # 04 Y:1995 | 04 | 1995 | INSTALL TIMERS AND/OR THERMOSTATS | $3,993 | $2,290 | Implemented |
TN0540 # 05 Y:1995 | 05 | 1995 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,361 | $0 | Not Implemented |
TN0540 # 06 Y:1995 | 06 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,119 | $1,845 | Not Implemented |
WV0047 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $379 | $952 | Implemented |
WV0047 # 02 Y:1995 | 02 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $504 | $700 | Not Implemented |
WV0047 # 03 Y:1995 | 03 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,908 | $670 | Not Implemented |
WV0047 # 04 Y:1995 | 04 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,126 | $1,000 | Implemented |
WV0047 # 05 Y:1995 | 05 | 1995 | USE SYNTHETIC LUBRICANT | $501 | $0 | Implemented |
WV0047 # 06 Y:1995 | 06 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $441 | $0 | Not Implemented |
WV0047 # 07 Y:1995 | 07 | 1995 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $154 | $20 | Not Implemented |
WV0047 # 08 Y:1995 | 08 | 1995 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $4,246 | $1,267 | Not Implemented |
WV0047 # 09 Y:1995 | 09 | 1995 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $1,063 | $30 | Implemented |
TN0557 # 01 Y:1995 | 01 | 1995 | INSTALL TIMERS AND/OR THERMOSTATS | $7,423 | $5,320 | Implemented |