Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,230
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0436 # 09 Y:2011 | 09 | 2011 | COVER OPEN TANKS | $1,610 | $5,000 | Not Implemented |
NC0436 # 10 Y:2011 | 10 | 2011 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $40,000 | $10,000 | Not Implemented |
UM0395 # 01 Y:2011 | 01 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $6,323 | $5,000 | Not Implemented |
UM0395 # 02 Y:2011 | 02 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $8,974 | $8,890 | Not Implemented |
UM0395 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,425 | $15,571 | Not Implemented |
UM0395 # 04 Y:2011 | 04 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $51,920 | $110,521 | Not Implemented |
UM0395 # 05 Y:2011 | 05 | 2011 | HEAT WATER WITH EXHAUST HEAT | $798 | $2,261 | Not Implemented |
UM0395 # 06 Y:2011 | 06 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $222 | $161 | Not Implemented |
UM0394 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,893 | $37,992 | Not Implemented |
UM0394 # 02 Y:2011 | 02 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $6,227 | $12,120 | Not Implemented |
UM0394 # 03 Y:2011 | 03 | 2011 | OPTIMIZE PLANT POWER FACTOR | $4,589 | $3,850 | Not Implemented |
UM0394 # 04 Y:2011 | 04 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,147 | $200 | Implemented |
UM0394 # 05 Y:2011 | 05 | 2011 | INSULATE BARE EQUIPMENT | $1,971 | $2,584 | Implemented |
UM0394 # 06 Y:2011 | 06 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,811 | $5,000 | Not Implemented |
UM0394 # 07 Y:2011 | 07 | 2011 | INSTALL OCCUPANCY SENSORS | $1,389 | $1,350 | Not Implemented |
UM0394 # 08 Y:2011 | 08 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $180 | $10 | Not Implemented |
UM0394 # 09 Y:2011 | 09 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,902 | $10,000 | Not Implemented |
MS0383 # 01 Y:2011 | 01 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,135 | $6,411 | Not Implemented |
NC0439 # 01 Y:2011 | 01 | 2011 | USE RADIANT HEATER FOR SPOT HEATING | $37,298 | $27,675 | Not Implemented |
NC0439 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $22,669 | $39,646 | Implemented |
NC0439 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $330 | $106 | Implemented |
NC0439 # 04 Y:2011 | 04 | 2011 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $3,390 | $4,200 | Implemented |
NC0439 # 05 Y:2011 | 05 | 2011 | DEVELOP A REPAIR/REPLACE POLICY | $4,934 | $2,393 | Implemented |
NC0439 # 06 Y:2011 | 06 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,486 | $1,800 | Not Implemented |
NC0439 # 07 Y:2011 | 07 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,953 | $100 | Implemented |