Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,230
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0082 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,923 | $18,044 | Implemented |
TT0082 # 02 Y:2011 | 02 | 2011 | INSTALL OCCUPANCY SENSORS | $4,602 | $28,092 | Not Implemented |
TT0082 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,878 | $11,643 | Not Implemented |
TT0082 # 04 Y:2011 | 04 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,256 | $1,480 | Implemented |
TT0082 # 05 Y:2011 | 05 | 2011 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,673 | $15 | Implemented |
TT0082 # 06 Y:2011 | 06 | 2011 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $2,834 | $1,500 | Not Implemented |
TT0082 # 07 Y:2011 | 07 | 2011 | REPLACE HIGH RESISTANCE DUCTS, PIPES, AND FITTINGS | $952 | $2,625 | Implemented |
MS0383 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $19,874 | $139,671 | Implemented |
MS0383 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,458 | $26,246 | Implemented |
MS0383 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,247 | $33,997 | Implemented |
MS0383 # 05 Y:2011 | 05 | 2011 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,584 | $659 | Not Implemented |
MS0383 # 06 Y:2011 | 06 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $757 | $281 | Implemented |
DL0077 # 01 Y:2011 | 01 | 2011 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $20,592 | $3,200 | Not Implemented |
DL0077 # 02 Y:2011 | 02 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $119,680 | $350,000 | Implemented |
DL0077 # 03 Y:2011 | 03 | 2011 | TURN OFF STEAM / HOT WATER LINES LEADING TO SPACE HEATING UNITS | $63,615 | $100,500 | Not Implemented |
DL0077 # 04 Y:2011 | 04 | 2011 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $31,497 | $800 | Not Implemented |
DL0077 # 05 Y:2011 | 05 | 2011 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $21,318 | $1,600 | Implemented |
DL0077 # 06 Y:2011 | 06 | 2011 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $24,600 | $18,000 | Not Implemented |
DL0077 # 07 Y:2011 | 07 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,771 | $11,600 | Implemented |
DL0077 # 08 Y:2011 | 08 | 2011 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $5,717 | $900 | Not Implemented |
SD0442 # 01 Y:2011 | 01 | 2011 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $727 | $100 | Not Implemented |
SD0442 # 02 Y:2011 | 02 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,100 | $100 | Not Implemented |
SD0442 # 03 Y:2011 | 03 | 2011 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $247 | $30 | Not Implemented |
SD0442 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,022 | $1,900 | Not Implemented |
SD0442 # 05 Y:2011 | 05 | 2011 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $11,760 | $26,500 | Not Implemented |