Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,263
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LS0222 # 03 Y:2022 | 03 | 2022 | REDUCE HEAT GAIN BY WINDOW TINTING | $6,372 | $2,100 | Implemented |
LS0222 # 04 Y:2022 | 04 | 2022 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $430 | $300 | Implemented |
LS0222 # 05 Y:2022 | 05 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $160 | $306 | Implemented |
LS0122 # 01 Y:2022 | 01 | 2022 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $13,696 | $0 | Implemented |
LS0122 # 02 Y:2022 | 02 | 2022 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $942 | $300 | Implemented |
LS0122 # 03 Y:2022 | 03 | 2022 | INSTALL OCCUPANCY SENSORS | $1,436 | $575 | Implemented |
LS0122 # 04 Y:2022 | 04 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $46,495 | $39,219 | Implemented |
LS0122 # 05 Y:2022 | 05 | 2022 | USE OPTIMUM THICKNESS INSULATION | $2,779 | $6,297 | Implemented |
LS2209 # 01 Y:2022 | 01 | 2022 | INSTALL TIMERS AND/OR THERMOSTATS | $1,858 | $75 | Not Implemented |
LS2209 # 02 Y:2022 | 02 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $33,222 | $5,575 | Implemented |
LS2209 # 03 Y:2022 | 03 | 2022 | USE PHOTOCELL CONTROLS | $3,323 | $740 | Not Implemented |
LS2209 # 04 Y:2022 | 04 | 2022 | USE SOLAR HEAT TO MAKE ELECTRICTY | $46,753 | $646,020 | Not Implemented |
LS2208 # 01 Y:2022 | 01 | 2022 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $378 | $10 | Not Implemented |
LS2208 # 02 Y:2022 | 02 | 2022 | INSTALL TIMERS AND/OR THERMOSTATS | $7,289 | $200 | Implemented |
LS2208 # 03 Y:2022 | 03 | 2022 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $651 | $50 | Not Implemented |
LS2208 # 04 Y:2022 | 04 | 2022 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,527 | $450 | Implemented |
LS2208 # 05 Y:2022 | 05 | 2022 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $975 | $240 | Not Implemented |
LS2208 # 06 Y:2022 | 06 | 2022 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $9,660 | $2,800 | Not Implemented |
LS2208 # 07 Y:2022 | 07 | 2022 | INSTALL OCCUPANCY SENSORS | $304 | $114 | Not Implemented |
LS2208 # 08 Y:2022 | 08 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,440 | $14,643 | Implemented |
LS2208 # 09 Y:2022 | 09 | 2022 | USE SOLAR HEAT TO MAKE ELECTRICTY | $15,212 | $215,340 | Not Implemented |
LS2207 # 01 Y:2022 | 01 | 2022 | INSTALL TIMERS AND/OR THERMOSTATS | $1,349 | $350 | Not Implemented |
LS2207 # 02 Y:2022 | 02 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,876 | $30,073 | Implemented |
LS2207 # 03 Y:2022 | 03 | 2022 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $3,432 | $32,496 | Implemented |
LS2207 # 04 Y:2022 | 04 | 2022 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $13,650 | $158,575 | Implemented |