Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,377
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0178 # 02 Y:1985 | 02 | 1985 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,524 | $4,000 | Implemented |
OK0178 # 03 Y:1985 | 03 | 1985 | USE RADIANT HEATER FOR SPOT HEATING | $1,400 | $2,120 | Implemented |
OK0178 # 04 Y:1985 | 04 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $178 | $150 | Implemented |
OK0178 # 05 Y:1985 | 05 | 1985 | COVER OPEN TANKS | $5,600 | $9,888 | Not Implemented |
OK0178 # 06 Y:1985 | 06 | 1985 | INSULATE BARE EQUIPMENT | $1,732 | $636 | Not Implemented |
OK0178 # 07 Y:1985 | 07 | 1985 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $244 | $200 | Implemented |
OK0178 # 08 Y:1985 | 08 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $64 | $55 | Implemented |
OK0178 # 09 Y:1985 | 09 | 1985 | OPTIMIZE PLANT POWER FACTOR | $528 | $1,795 | Not Implemented |
OK0178 # 10 Y:1985 | 10 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $579 | $250 | Implemented |
OK0179 # 01 Y:1985 | 01 | 1985 | OPTIMIZE PLANT POWER FACTOR | $1,296 | $3,847 | Not Implemented |
OK0179 # 02 Y:1985 | 02 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $271 | $600 | Implemented |
OK0179 # 03 Y:1985 | 03 | 1985 | USE RADIANT HEATER FOR SPOT HEATING | $12,890 | $4,700 | Implemented |
OK0179 # 04 Y:1985 | 04 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $215 | $248 | Implemented |
OK0180 # 01 Y:1985 | 01 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $565 | $120 | Implemented |
OK0180 # 02 Y:1985 | 02 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $1,599 | $2,100 | Implemented |
OK0180 # 03 Y:1985 | 03 | 1985 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $579 | $0 | Implemented |
OK0180 # 04 Y:1985 | 04 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $781 | $186 | Implemented |
OK0180 # 05 Y:1985 | 05 | 1985 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $4,770 | $4,400 | Implemented |
OK0180 # 06 Y:1985 | 06 | 1985 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $3,695 | $2,100 | Implemented |
OK0180 # 07 Y:1985 | 07 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,381 | $29,961 | Implemented |
OK0182 # 01 Y:1985 | 01 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $225 | $310 | Implemented |
OK0182 # 02 Y:1985 | 02 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,969 | $7,785 | Not Implemented |
OK0182 # 03 Y:1985 | 03 | 1985 | INSTALL SET-BACK TIMERS | $119 | $225 | Not Implemented |
OK0182 # 04 Y:1985 | 04 | 1985 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,756 | $6,480 | Not Implemented |
OK0182 # 05 Y:1985 | 05 | 1985 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $680 | $325 | Implemented |