Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,942
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0095 # 06 Y:1996 | 06 | 1996 | TURN OFF EQUIPMENT WHEN NOT IN USE | $580 | $0 | Implemented |
WV0095 # 07 Y:1996 | 07 | 1996 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $8,019 | $2,940 | Not Implemented |
WV0095 # 08 Y:1996 | 08 | 1996 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,432 | $2,800 | Not Implemented |
WV0095 # 09 Y:1996 | 09 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $11,260 | $9,000 | Implemented |
UD0493 # 01 Y:1996 | 01 | 1996 | KEEP BOILER TUBES CLEAN | $2,375 | $500 | Implemented |
UD0493 # 02 Y:1996 | 02 | 1996 | REPAIR OR REPLACE STEAM TRAPS | $10,368 | $9,000 | Implemented |
UD0493 # 03 Y:1996 | 03 | 1996 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $14,952 | $2,500 | Implemented |
UD0493 # 04 Y:1996 | 04 | 1996 | USE PHOTOCELL CONTROLS | $1,741 | $1,375 | Implemented |
UD0493 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,907 | $15,000 | Implemented |
UD0493 # 06 Y:1996 | 06 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,431 | $5,975 | Implemented |
UD0493 # 07 Y:1996 | 07 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,554 | $5,953 | Implemented |
UD0493 # 08 Y:1996 | 08 | 1996 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $11,264 | $45,000 | Not Implemented |
UD0493 # 09 Y:1996 | 09 | 1996 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $14,773 | $34,000 | Implemented |
UD0492 # 01 Y:1996 | 01 | 1996 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $552 | $0 | Implemented |
UD0492 # 02 Y:1996 | 02 | 1996 | DISCONNECT BALLASTS | $2,618 | $0 | Not Implemented |
UD0492 # 03 Y:1996 | 03 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,723 | $24,961 | Implemented |
UD0492 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,905 | $7,030 | Implemented |
UD0492 # 05 Y:1996 | 05 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $14,226 | $6,000 | Implemented |
UD0490 # 01 Y:1996 | 01 | 1996 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $55,282 | $12,000 | Implemented |
UD0490 # 02 Y:1996 | 02 | 1996 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,981 | $0 | Not Implemented |
UD0490 # 03 Y:1996 | 03 | 1996 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,080 | $100 | Not Implemented |
UD0490 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,214 | $11,929 | Not Implemented |
UD0490 # 05 Y:1996 | 05 | 1996 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $3,300 | $500 | Not Implemented |
UD0489 # 01 Y:1996 | 01 | 1996 | OPTIMIZE PLANT POWER FACTOR | $2,203 | $3,000 | Not Implemented |
UD0489 # 02 Y:1996 | 02 | 1996 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $11,117 | $15,000 | Implemented |