Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,602
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0163 # 04 Y:1992 | 04 | 1992 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $620 | $270 | Not Implemented |
AM0163 # 05 Y:1992 | 05 | 1992 | INSTALL TIMERS AND/OR THERMOSTATS | $330 | $0 | Implemented |
AM0164 # 01 Y:1992 | 01 | 1992 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $93,089 | $0 | Implemented |
AM0164 # 02 Y:1992 | 02 | 1992 | OPTIMIZE PLANT POWER FACTOR | $44,815 | $64,750 | Implemented |
AM0164 # 03 Y:1992 | 03 | 1992 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $19,440 | $850 | Not Implemented |
AM0164 # 04 Y:1992 | 04 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,158 | $1,030 | Implemented |
AM0164 # 05 Y:1992 | 05 | 1992 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $2,200 | $419 | Not Implemented |
AM0164 # 06 Y:1992 | 06 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,140 | $910 | Implemented |
AM0161 # 01 Y:1992 | 01 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,600 | $630 | Implemented |
AM0161 # 02 Y:1992 | 02 | 1992 | REDUCE LOAD ON ELECTRICAL CONDUCTOR TO REDUCE HEATING LOSSES | $4,700 | $2,255 | Not Implemented |
AM0161 # 03 Y:1992 | 03 | 1992 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,855 | $0 | Implemented |
AM0161 # 04 Y:1992 | 04 | 1992 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,290 | $985 | Implemented |
AM0161 # 05 Y:1992 | 05 | 1992 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,420 | $0 | Implemented |
AM0161 # 06 Y:1992 | 06 | 1992 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $2,205 | $5,050 | Not Implemented |
AM0161 # 07 Y:1992 | 07 | 1992 | TURN OFF EQUIPMENT WHEN NOT IN USE | $690 | $0 | Implemented |
AM0161 # 08 Y:1992 | 08 | 1992 | INSTALL TIMERS AND/OR THERMOSTATS | $280 | $450 | Implemented |
AM0162 # 01 Y:1992 | 01 | 1992 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,720 | $782 | Implemented |
AM0162 # 02 Y:1992 | 02 | 1992 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $1,150 | $5,746 | Implemented |
AM0162 # 03 Y:1992 | 03 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,010 | $300 | Implemented |
AM0162 # 04 Y:1992 | 04 | 1992 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $700 | $215 | Implemented |
AM0159 # 01 Y:1992 | 01 | 1992 | OPTIMIZE PLANT POWER FACTOR | $9,900 | $26,500 | Implemented |
AM0159 # 02 Y:1992 | 02 | 1992 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,980 | $22,500 | Not Implemented |
AM0159 # 03 Y:1992 | 03 | 1992 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,680 | $14,340 | Not Implemented |
AM0159 # 04 Y:1992 | 04 | 1992 | INSTALL SET-BACK TIMERS | $2,200 | $0 | Implemented |
AM0159 # 05 Y:1992 | 05 | 1992 | INSULATE BARE EQUIPMENT | $490 | $690 | Not Implemented |