Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,515
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0017 # 05 Y:2008 | 05 | 2008 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $6,947 | $17,385 | Not Implemented |
NC0367 # 01 Y:2007 | 01 | 2007 | BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT | $43,971 | $100,000 | Not Implemented |
NC0367 # 02 Y:2007 | 02 | 2007 | USE STEAM PRESSURE REDUCTION TO GENERATE POWER | $9,176 | $30,000 | Not Implemented |
NC0367 # 03 Y:2007 | 03 | 2007 | DEVELOP A REPAIR/REPLACE POLICY | $588 | $1,297 | Implemented |
NC0367 # 04 Y:2007 | 04 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,742 | $6,500 | Not Implemented |
NC0367 # 05 Y:2007 | 05 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,263 | $5,800 | Not Implemented |
NC0367 # 06 Y:2007 | 06 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,600 | $100 | Implemented |
NC0367 # 07 Y:2007 | 07 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $389 | $960 | Implemented |
NC0367 # 08 Y:2007 | 08 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,438 | $76,397 | Not Implemented |
NC0367 # 09 Y:2007 | 09 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,310 | $50 | Implemented |
NC0367 # 10 Y:2007 | 10 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,690 | $5,576 | Not Implemented |
NC0366 # 01 Y:2007 | 01 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $81,321 | $400,000 | Not Implemented |
NC0366 # 02 Y:2007 | 02 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $61,491 | $250,000 | Not Implemented |
NC0366 # 03 Y:2007 | 03 | 2007 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $18,013 | $60,000 | Not Implemented |
NC0366 # 04 Y:2007 | 04 | 2007 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $71,297 | $280,000 | Implemented |
NC0366 # 05 Y:2007 | 05 | 2007 | INCREASE AMOUNT OF CONDENSATE RETURNED | $12,430 | $12,000 | Implemented |
NC0365 # 01 Y:2007 | 01 | 2007 | REDUCE VENTILATION AIR | $11,968 | $28,000 | Implemented |
NC0365 # 02 Y:2007 | 02 | 2007 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $11,898 | $7,000 | Implemented |
NC0365 # 03 Y:2007 | 03 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,542 | $100 | Implemented |
NC0365 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,833 | $71,577 | Not Implemented |
NC0365 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,788 | $50 | Implemented |
NC0365 # 06 Y:2007 | 06 | 2007 | OPTIMIZE PLANT POWER FACTOR | $6,133 | $12,000 | Implemented |
NC0360 # 01 Y:2007 | 01 | 2007 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $20,317 | $10,000 | Implemented |
NC0360 # 02 Y:2007 | 02 | 2007 | REPAIR AND ELIMINATE STEAM LEAKS | $9,594 | $2,250 | Implemented |
NC0360 # 03 Y:2007 | 03 | 2007 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $35,946 | $33,785 | Not Implemented |