Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,980
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0288 # 02 Y:1989 | 02 | 1989 | REDUCE VENTILATION AIR | $30,846 | $10,000 | Implemented |
UD0288 # 03 Y:1989 | 03 | 1989 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $23,159 | $10,000 | Implemented |
UD0288 # 04 Y:1989 | 04 | 1989 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $31,629 | $90,000 | Not Implemented |
UD0288 # 05 Y:1989 | 05 | 1989 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $803 | $0 | Implemented |
UD0289 # 01 Y:1989 | 01 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $3,618 | $1,000 | Not Implemented |
UD0289 # 02 Y:1989 | 02 | 1989 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,453 | $0 | Implemented |
UD0289 # 03 Y:1989 | 03 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,150 | $4,000 | Not Implemented |
UD0289 # 04 Y:1989 | 04 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $791 | $1,000 | Not Implemented |
UD0289 # 05 Y:1989 | 05 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $356 | $75 | Implemented |
UD0289 # 06 Y:1989 | 06 | 1989 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $9,331 | $25,000 | Not Implemented |
UD0289 # 07 Y:1989 | 07 | 1989 | RECOVER AND REUSE COOLING WATER | $5,791 | $20,000 | Not Implemented |
UD0286 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,690 | $0 | Implemented |
UD0286 # 02 Y:1989 | 02 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,354 | $0 | Implemented |
UD0286 # 03 Y:1989 | 03 | 1989 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $543 | $0 | Implemented |
UD0286 # 04 Y:1989 | 04 | 1989 | USE SMALL NUMBER OF HIGH OUTPUT UNITS INSTEAD OF MANY SMALL INEFFICIENT UNITS | $1,105 | $6,000 | Not Implemented |
UD0286 # 05 Y:1989 | 05 | 1989 | OPTIMIZE PLANT POWER FACTOR | $6,809 | $12,000 | Implemented |
UD0286 # 06 Y:1989 | 06 | 1989 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $117,912 | $60,000 | Implemented |
UD0286 # 07 Y:1989 | 07 | 1989 | INSTALL STORM WINDOWS AND DOORS | $47,948 | $47,000 | Not Implemented |
UD0286 # 08 Y:1989 | 08 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $9,312 | $0 | Implemented |
UD0283 # 01 Y:1989 | 01 | 1989 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,105 | $2,000 | Implemented |
UD0283 # 02 Y:1989 | 02 | 1989 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $5,833 | $3,000 | Implemented |
UD0283 # 03 Y:1989 | 03 | 1989 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $738 | $0 | Implemented |
UD0283 # 04 Y:1989 | 04 | 1989 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $602 | $400 | Implemented |
UD0284 # 01 Y:1989 | 01 | 1989 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $38,356 | $20,000 | Implemented |
UD0284 # 02 Y:1989 | 02 | 1989 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,285 | $0 | Implemented |