Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,602
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0067 # 02 Y:1989 | 02 | 1989 | REPAIR AND ELIMINATE STEAM LEAKS | $4,380 | $800 | Implemented |
AM0067 # 03 Y:1989 | 03 | 1989 | INSTALL SET-BACK TIMERS | $3,860 | $0 | Implemented |
AM0067 # 04 Y:1989 | 04 | 1989 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $2,932 | $175 | Implemented |
AM0067 # 06 Y:1989 | 06 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $900 | $800 | Not Implemented |
AM0067 # 07 Y:1989 | 07 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $154 | $91 | Not Implemented |
AM0067 # 08 Y:1989 | 08 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $285 | $83 | Not Implemented |
AM0067 # 09 Y:1989 | 09 | 1989 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $94 | $500 | Not Implemented |
AM0068 # 01 Y:1989 | 01 | 1989 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $40,430 | $24,600 | Implemented |
AM0068 # 02 Y:1989 | 02 | 1989 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $9,210 | $16,500 | Implemented |
AM0068 # 03 Y:1989 | 03 | 1989 | INSTALL SET-BACK TIMERS | $2,180 | $0 | Implemented |
AM0068 # 04 Y:1989 | 04 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $890 | $1,000 | Implemented |
AM0068 # 05 Y:1989 | 05 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $347 | $97 | Implemented |
AM0068 # 06 Y:1989 | 06 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $330 | $295 | Implemented |
AM0063 # 01 Y:1989 | 01 | 1989 | PAY UTILITY BILLS ON TIME | $1,269 | $0 | Implemented |
AM0063 # 02 Y:1989 | 02 | 1989 | INSTALL SET-BACK TIMERS | $1,250 | $160 | Implemented |
AM0063 # 04 Y:1989 | 04 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $150 | $238 | Not Implemented |
AM0063 # 05 Y:1989 | 05 | 1989 | INSTALL SET-BACK TIMERS | $450 | $0 | Implemented |
AM0063 # 06 Y:1989 | 06 | 1989 | IMPROVE LUBRICATION PRACTICES | $398 | $0 | Not Implemented |
AM0063 # 07 Y:1989 | 07 | 1989 | AIR CONDITION ONLY SPACE NECESSARY | $110 | $0 | Not Implemented |
AM0063 # 08 Y:1989 | 08 | 1989 | INSTALL SET-BACK TIMERS | $53 | $69 | Not Implemented |
AM0064 # 01 Y:1989 | 01 | 1989 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $8,120 | $25,000 | Implemented |
AM0064 # 02 Y:1989 | 02 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,348 | $205 | Implemented |
AM0064 # 03 Y:1989 | 03 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,709 | $1,500 | Implemented |
AM0064 # 04 Y:1989 | 04 | 1989 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $4,550 | $8,250 | Implemented |
AM0064 # 05 Y:1989 | 05 | 1989 | INSULATE BARE EQUIPMENT | $2,285 | $3,250 | Implemented |