Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

9,942

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0130 # 02 Y:1984 02 1984 REDUCE GLAZED AREAS IN BUILDINGS $7,927 $5,145 Not Implemented
UD0130 # 03 Y:1984 03 1984 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $466 $578 Not Implemented
UD0130 # 04 Y:1984 04 1984 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $26,850 $30,000 Not Implemented
UD0125 # 01 Y:1984 01 1984 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $11,583 $11,079 Implemented
UD0125 # 02 Y:1984 02 1984 COVER OPEN TANKS $1,611 $1,080 Implemented
UD0125 # 03 Y:1984 03 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,474 $5,156 Implemented
UD0126 # 01 Y:1984 01 1984 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $2,095 $1,000 Implemented
UD0126 # 02 Y:1984 02 1984 DISCONNECT BALLASTS $1,386 $2,310 Implemented
UD0121 # 01 Y:1984 01 1984 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $5,826 $28,200 Not Implemented
UD0121 # 02 Y:1984 02 1984 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $4,578 $15,000 Not Implemented
UD0122 # 01 Y:1984 01 1984 INSTALL TIMERS AND/OR THERMOSTATS $8,037 $2,800 Implemented
UD0122 # 02 Y:1984 02 1984 RECOVER WASTE HEAT FROM EQUIPMENT $1,523 $1,000 Implemented
UD0122 # 03 Y:1984 03 1984 USE DIRECT AIR SUPPLY TO EXHAUST HOODS $530 $1,000 Not Implemented
UD0122 # 04 Y:1984 04 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $177 $73 Implemented
UD0123 # 01 Y:1984 01 1984 TURN OFF EQUIPMENT WHEN NOT IN USE $1,488 $0 Implemented
UD0123 # 02 Y:1984 02 1984 INSTALL TIMERS AND/OR THERMOSTATS $3,250 $3,000 Not Implemented
UD0123 # 03 Y:1984 03 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,466 $4,600 Implemented
UD0123 # 04 Y:1984 04 1984 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $347 $600 Implemented
UD0123 # 05 Y:1984 05 1984 RECOVER WASTE HEAT FROM EQUIPMENT $664 $2,000 Not Implemented
UD0124 # 01 Y:1984 01 1984 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $6,949 $30,000 Implemented
UD0124 # 02 Y:1984 02 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,158 $1,674 Implemented
UD0124 # 03 Y:1984 03 1984 INSULATE BARE EQUIPMENT $1,892 $1,000 Implemented
UD0117 # 01 Y:1984 01 1984 REDESIGN PROCESS $9,920 $18,000 Not Implemented
UD0117 # 02 Y:1984 02 1984 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $3,837 $2,000 Not Implemented
UD0117 # 03 Y:1984 03 1984 INSTALL STORM WINDOWS AND DOORS $18,493 $22,385 Implemented