Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
307
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0188 # 06 Y:1993 | 06 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $556 | $1,600 | Implemented |
WI0188 # 05 Y:1993 | 05 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $594 | $0 | Not Implemented |
WI0188 # 04 Y:1993 | 04 | 1993 | INSTALL OCCUPANCY SENSORS | $665 | $225 | Not Implemented |
WI0188 # 03 Y:1993 | 03 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,228 | $1,399 | Not Implemented |
WI0188 # 02 Y:1993 | 02 | 1993 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,978 | $600 | Implemented |
WI0188 # 01 Y:1993 | 01 | 1993 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,239 | $2,000 | Implemented |
IA0063 # 02 Y:1993 | 02 | 1993 | INSTALL DIRECT ACTING UNITS IN PLACE OF COMPRESSED AIR PRESSURE SYSTEM IN SAFETY SYSTEM | $5,451 | $3,230 | Not Implemented |
IA0063 # 01 Y:1993 | 01 | 1993 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $21,047 | $82,940 | Implemented |
IA0063 # 11 Y:1993 | 11 | 1993 | INSTALL TIMERS AND/OR THERMOSTATS | $595 | $1,350 | Implemented |
IA0063 # 10 Y:1993 | 10 | 1993 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $556 | $215 | Implemented |
IA0063 # 09 Y:1993 | 09 | 1993 | INSTALL OCCUPANCY SENSORS | $473 | $665 | Implemented |
IA0063 # 08 Y:1993 | 08 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $528 | $840 | Not Implemented |
IA0063 # 07 Y:1993 | 07 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $165 | $0 | Not Implemented |
IA0063 # 05 Y:1993 | 05 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $402 | $925 | Implemented |
IA0063 # 04 Y:1993 | 04 | 1993 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $2,421 | $685 | Implemented |
IA0063 # 03 Y:1993 | 03 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,186 | $100 | Implemented |
IA0063 # 06 Y:1993 | 06 | 1993 | USE RADIANT HEATER FOR SPOT HEATING | $2,719 | $10,200 | Implemented |
WI0187 # 09 Y:1993 | 09 | 1993 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $255 | $600 | Not Implemented |
WI0187 # 08 Y:1993 | 08 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $387 | $120 | Implemented |
WI0187 # 07 Y:1993 | 07 | 1993 | INSTALL OCCUPANCY SENSORS | $167 | $150 | Not Implemented |
WI0187 # 06 Y:1993 | 06 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $841 | $2,800 | Not Implemented |
WI0187 # 03 Y:1993 | 03 | 1993 | INSULATE BARE EQUIPMENT | $278 | $40 | Implemented |
WI0187 # 01 Y:1993 | 01 | 1993 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $2,534 | $750 | Implemented |
WI0187 # 02 Y:1993 | 02 | 1993 | INSULATE BARE EQUIPMENT | $343 | $184 | Implemented |
WI0187 # 05 Y:1993 | 05 | 1993 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $2,023 | $5,000 | Not Implemented |