Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
6,055
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UL0145 # 03 Y:1995 | 03 | 1995 | OPTIMIZE PLANT POWER FACTOR | $30,246 | $21,220 | Not Implemented |
UL0145 # 02 Y:1995 | 02 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,159 | $8,988 | Not Implemented |
UL0145 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,040 | $1,151 | Not Implemented |
MO0165 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,744 | $3,350 | Implemented |
MO0165 # 02 Y:1995 | 02 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,038 | $12,424 | Not Implemented |
MO0165 # 03 Y:1995 | 03 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,634 | $8,046 | Not Implemented |
MO0165 # 04 Y:1995 | 04 | 1995 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,357 | $500 | Implemented |
MO0165 # 05 Y:1995 | 05 | 1995 | MINIMIZE BOILER BLOWDOWN WITH BETTER FEEDWATER TREATMENT | $1,460 | $775 | Implemented |
MO0165 # 06 Y:1995 | 06 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,308 | $471 | Not Implemented |
MO0165 # 07 Y:1995 | 07 | 1995 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,308 | $40 | Not Implemented |
MO0165 # 08 Y:1995 | 08 | 1995 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $918 | $1,780 | Not Implemented |
MO0165 # 09 Y:1995 | 09 | 1995 | USE RE-USABLE FILTERS | $3,640 | $623 | Not Implemented |
MO0165 # 10 Y:1995 | 10 | 1995 | TREAT AND REUSE RINSE WATERS | $1,400 | $1,450 | Implemented |
OR0255 # 11 Y:1995 | 11 | 1995 | MINIMIZE WATER USAGE | $1,279 | $434 | Not Implemented |
OR0255 # 10 Y:1995 | 10 | 1995 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $1,952 | $489 | Not Implemented |
OR0255 # 09 Y:1995 | 09 | 1995 | MINIMIZE WATER USAGE | $3,344 | $600 | Not Implemented |
OR0255 # 08 Y:1995 | 08 | 1995 | MINIMIZE WATER USAGE | $3,418 | $148 | Implemented |
OR0255 # 07 Y:1995 | 07 | 1995 | MINIMIZE WATER USAGE | $5,927 | $1,153 | Implemented |
OR0255 # 06 Y:1995 | 06 | 1995 | USE ABSORPTION, EXTRACTION TO REMOVE CONTAMINANTS | $104,000 | $250,000 | Not Implemented |
OR0255 # 05 Y:1995 | 05 | 1995 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $8,071 | $0 | Implemented |
OR0255 # 04 Y:1995 | 04 | 1995 | OPTIMIZE PLANT POWER FACTOR | $1,080 | $3,600 | Not Implemented |
OR0255 # 03 Y:1995 | 03 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,209 | $3,511 | Implemented |
OR0255 # 02 Y:1995 | 02 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,688 | $4,179 | Not Implemented |
OR0255 # 01 Y:1995 | 01 | 1995 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,563 | $0 | Implemented |
CO0350 # 06 Y:1995 | 06 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $290 | $610 | Not Implemented |