Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,644
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0439 # 03 Y:2017 | 03 | 2017 | USE RADIANT HEATER FOR SPOT HEATING | $17,188 | $9,084 | Not Implemented |
LE0439 # 04 Y:2017 | 04 | 2017 | TREAT AND REUSE RINSE WATERS | $35,049 | $30,000 | Not Implemented |
LE0439 # 05 Y:2017 | 05 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,559 | $4,244 | Not Implemented |
LE0439 # 06 Y:2017 | 06 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,992 | $5,000 | Implemented |
LE0439 # 07 Y:2017 | 07 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,903 | $21,654 | Implemented |
LE0439 # 08 Y:2017 | 08 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $31,023 | $105,761 | Not Implemented |
WV0548 # 01 Y:2017 | 01 | 2017 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $9,343 | $2,478 | Not Implemented |
WV0548 # 02 Y:2017 | 02 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,922 | $41,392 | Implemented |
WV0548 # 03 Y:2017 | 03 | 2017 | INSTALL SENSORS TO DETECT AND AVOID JAMS | $6,579 | $1,611 | Not Implemented |
WV0548 # 04 Y:2017 | 04 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,331 | $0 | Implemented |
WV0548 # 05 Y:2017 | 05 | 2017 | MINIMIZE WATER USAGE | $4,164 | $750 | Not Implemented |
WV0548 # 06 Y:2017 | 06 | 2017 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $3,443 | $1,000 | Implemented |
WV0548 # 07 Y:2017 | 07 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,545 | $8,388 | Implemented |
WV0548 # 08 Y:2017 | 08 | 2017 | UPGRADE CONTROLS ON COMPRESSORS | $2,479 | $10,000 | Not Implemented |
WV0548 # 09 Y:2017 | 09 | 2017 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,157 | $3,278 | Not Implemented |
WV0548 # 10 Y:2017 | 10 | 2017 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,140 | $1,058 | Not Implemented |
WV0548 # 11 Y:2017 | 11 | 2017 | DEVELOP A REPAIR/REPLACE POLICY | $1,024 | $699 | Implemented |
WV0548 # 12 Y:2017 | 12 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $863 | $431 | Implemented |
WV0548 # 13 Y:2017 | 13 | 2017 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $260 | $850 | Implemented |
LE0436 # 01 Y:2017 | 01 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,786 | $1,000 | Implemented |
LE0436 # 02 Y:2017 | 02 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,929 | $15,805 | Implemented |
LE0436 # 03 Y:2017 | 03 | 2017 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $6,297 | $7,000 | Not Implemented |
LE0436 # 04 Y:2017 | 04 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,174 | $3,600 | Implemented |
LE0436 # 05 Y:2017 | 05 | 2017 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $23,395 | $32,000 | Not Implemented |
LE0436 # 06 Y:2017 | 06 | 2017 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $2,358 | $7,000 | Not Implemented |