Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,317
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0407 # 09 Y:2010 | 09 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,209 | $7,158 | Implemented |
WV0407 # 10 Y:2010 | 10 | 2010 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $4,353 | $1,000 | Implemented |
WV0404 # 07 Y:2010 | 07 | 2010 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,958 | $3,400 | Implemented |
WV0404 # 08 Y:2010 | 08 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,603 | $1,272 | Not Implemented |
WV0404 # 01 Y:2010 | 01 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $795,452 | $529,924 | Not Implemented |
WV0404 # 02 Y:2010 | 02 | 2010 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $464,158 | $180,000 | Not Implemented |
WV0404 # 03 Y:2010 | 03 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $151,596 | $109,360 | Not Implemented |
WV0404 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $45,647 | $65,720 | Implemented |
WV0404 # 05 Y:2010 | 05 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $31,815 | $12,720 | Implemented |
WV0404 # 06 Y:2010 | 06 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $27,235 | $6,000 | Implemented |
WV0402 # 01 Y:2010 | 01 | 2010 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $63,671 | $114,000 | Not Implemented |
WV0402 # 02 Y:2010 | 02 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $32,843 | $25,000 | Not Implemented |
WV0402 # 03 Y:2010 | 03 | 2010 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $16,488 | $0 | Implemented |
WV0402 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,346 | $9,200 | Implemented |
WV0402 # 05 Y:2010 | 05 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $13,296 | $2,000 | Not Implemented |
WV0402 # 06 Y:2010 | 06 | 2010 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $12,095 | $4,000 | Not Implemented |
WV0402 # 07 Y:2010 | 07 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,390 | $0 | Implemented |
WV0399 # 01 Y:2010 | 01 | 2010 | BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT | $215,411 | $540,000 | Not Implemented |
WV0399 # 02 Y:2010 | 02 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $154,014 | $106,000 | Not Implemented |
WV0399 # 03 Y:2010 | 03 | 2010 | COVER OPEN TANKS | $83,144 | $7,290 | Implemented |
WV0399 # 04 Y:2010 | 04 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $37,930 | $39,900 | Implemented |
WV0399 # 05 Y:2010 | 05 | 2010 | DEVELOP A REPAIR/REPLACE POLICY | $18,121 | $1,644 | Implemented |
WV0399 # 06 Y:2010 | 06 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $16,812 | $0 | Implemented |
WV0399 # 07 Y:2010 | 07 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,889 | $0 | Implemented |
WV0399 # 08 Y:2010 | 08 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $6,515 | $1,717 | Implemented |