ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0423 # 01 Y:1990 | 01 | 1990 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,280 | $0 | Not Implemented |
GT0423 # 02 Y:1990 | 02 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,135 | $10,029 | Implemented |
GT0423 # 03 Y:1990 | 03 | 1990 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $668 | $500 | Implemented |
GT0423 # 04 Y:1990 | 04 | 1990 | IMPROVE LUBRICATION PRACTICES | $2,000 | $0 | Implemented |
GT0423 # 05 Y:1990 | 05 | 1990 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,600 | $2,000 | Implemented |
GT0423 # 06 Y:1990 | 06 | 1990 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,500 | $500 | Implemented |
GT0423 # 07 Y:1990 | 07 | 1990 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $2,200 | $1,600 | Implemented |
GT0423 # 08 Y:1990 | 08 | 1990 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $3,250 | $7,000 | Implemented |
GT0423 # 09 Y:1990 | 09 | 1990 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $15,684 | $11,000 | Not Implemented |
TN0406 # 01 Y:1990 | 01 | 1990 | REDESIGN PROCESS | $5,552 | $21,192 | Not Implemented |
TN0406 # 02 Y:1990 | 02 | 1990 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $4,734 | $2,000 | Not Implemented |
TN0406 # 03 Y:1990 | 03 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,172 | $10,820 | Not Implemented |
TN0406 # 04 Y:1990 | 04 | 1990 | INSTALL SET-BACK TIMERS | $2,139 | $0 | Not Implemented |
TN0406 # 05 Y:1990 | 05 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,202 | $0 | Not Implemented |
TN0406 # 06 Y:1990 | 06 | 1990 | KEEP LAMPS AND REFLECTORS CLEAN | $783 | $1,275 | Not Implemented |
TN0406 # 07 Y:1990 | 07 | 1990 | KEEP LAMPS AND REFLECTORS CLEAN | $461 | $1,124 | Not Implemented |
TN0406 # 08 Y:1990 | 08 | 1990 | TURN OFF EQUIPMENT WHEN NOT IN USE | $721 | $1,320 | Not Implemented |
TN0406 # 09 Y:1990 | 09 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $769 | $653 | Not Implemented |
TN0406 # 10 Y:1990 | 10 | 1990 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $264 | $335 | Not Implemented |
TN0406 # 11 Y:1990 | 11 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $240 | $120 | Not Implemented |
TN0412 # 01 Y:1990 | 01 | 1990 | USE MINIMUM STEAM OPERATING PRESSURE | $46,500 | $0 | Implemented |
TN0412 # 02 Y:1990 | 02 | 1990 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $11,598 | $10,600 | Not Implemented |
TN0412 # 03 Y:1990 | 03 | 1990 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $7,159 | $0 | Implemented |
TN0412 # 04 Y:1990 | 04 | 1990 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,317 | $1,500 | Implemented |
TN0412 # 05 Y:1990 | 05 | 1990 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $8,740 | $2,460 | Not Implemented |