Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,597
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0972 # 06 Y:2017 | 06 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,488 | $300 | Implemented |
UD0972 # 07 Y:2017 | 07 | 2017 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $454 | $1,400 | Not Implemented |
AS0445 # 01 Y:2017 | 01 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $19,548 | $4,394 | Not Implemented |
AS0445 # 02 Y:2017 | 02 | 2017 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $2,708 | $12,650 | Not Implemented |
AS0445 # 03 Y:2017 | 03 | 2017 | INSTALL DIRECT ACTING UNITS IN PLACE OF COMPRESSED AIR PRESSURE SYSTEM IN SAFETY SYSTEM | $813 | $675 | Not Implemented |
UD0971 # 01 Y:2017 | 01 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,580 | $0 | Implemented |
UD0971 # 02 Y:2017 | 02 | 2017 | USE MINIMUM STEAM OPERATING PRESSURE | $10,210 | $50 | Not Implemented |
UD0971 # 03 Y:2017 | 03 | 2017 | COVER OPEN TANKS | $8,336 | $2,760 | Not Implemented |
UD0971 # 04 Y:2017 | 04 | 2017 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $972 | $50 | Implemented |
UD0971 # 05 Y:2017 | 05 | 2017 | ADD AREA LIGHTING SWITCHES | $2,213 | $500 | Not Implemented |
UD0971 # 06 Y:2017 | 06 | 2017 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $400 | $681 | Not Implemented |
UD0971 # 07 Y:2017 | 07 | 2017 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,936 | $3,000 | Not Implemented |
UD0971 # 08 Y:2017 | 08 | 2017 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $51,180 | $3,650 | Not Implemented |
UD0971 # 09 Y:2017 | 09 | 2017 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $36,055 | $178,850 | Not Implemented |
UD0971 # 10 Y:2017 | 10 | 2017 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,985 | $22,000 | Not Implemented |
NL0008 # 01 Y:2017 | 01 | 2017 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,345 | $0 | Implemented |
NL0008 # 02 Y:2017 | 02 | 2017 | INSTALL OCCUPANCY SENSORS | $1,330 | $14,200 | Implemented |
NL0008 # 03 Y:2017 | 03 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $457 | $4,600 | Implemented |
NL0008 # 04 Y:2017 | 04 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $111 | $0 | Not Implemented |
WM0108 # 01 Y:2017 | 01 | 2017 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $8,966 | $6,300 | Not Implemented |
WM0108 # 02 Y:2017 | 02 | 2017 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $7,431 | $0 | Not Implemented |
WM0108 # 03 Y:2017 | 03 | 2017 | USE SYNTHETIC LUBRICANT | $4,603 | $4,815 | Not Implemented |
WM0108 # 04 Y:2017 | 04 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,022 | $4,500 | Not Implemented |
WM0108 # 05 Y:2017 | 05 | 2017 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $778 | $548 | Not Implemented |
MA0783 # 01 Y:2017 | 01 | 2017 | USE SOLAR HEAT FOR HEAT | $17,909 | $431,094 | Not Implemented |