Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,666
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0040 # 09 Y:2009 | 09 | 2009 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $224 | $1,445 | Not Implemented |
NC0391 # 01 Y:2009 | 01 | 2009 | INCREASE AMOUNT OF CONDENSATE RETURNED | $5,716 | $10,000 | Implemented |
NC0391 # 02 Y:2009 | 02 | 2009 | FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM | $18,020 | $25,000 | Implemented |
NC0391 # 03 Y:2009 | 03 | 2009 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $5,889 | $6,500 | Not Implemented |
NC0391 # 04 Y:2009 | 04 | 2009 | DEVELOP A REPAIR/REPLACE POLICY | $4,320 | $6,886 | Not Implemented |
NC0391 # 05 Y:2009 | 05 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $257 | $100 | Implemented |
NC0391 # 06 Y:2009 | 06 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,946 | $59,958 | Not Implemented |
OK0778 # 01 Y:2009 | 01 | 2009 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $171,482 | $47,731 | Implemented |
OK0778 # 02 Y:2009 | 02 | 2009 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,464 | $1,266 | Implemented |
OK0778 # 03 Y:2009 | 03 | 2009 | REPAIR AND ELIMINATE STEAM LEAKS | $13,933 | $525 | Implemented |
OK0778 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,111 | $5,417 | Implemented |
OK0778 # 05 Y:2009 | 05 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $412 | $0 | Implemented |
IA0442 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,396 | $1,012 | Not Implemented |
IA0442 # 02 Y:2009 | 02 | 2009 | INSTALL OCCUPANCY SENSORS | $1,053 | $1,195 | Not Implemented |
IA0442 # 03 Y:2009 | 03 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,623 | $25 | Implemented |
IA0442 # 04 Y:2009 | 04 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,409 | $1,149 | Not Implemented |
SF0376 # 01 Y:2009 | 01 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $397 | $535 | Implemented |
SF0376 # 02 Y:2009 | 02 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $34,155 | $110,307 | Implemented |
SF0376 # 03 Y:2009 | 03 | 2009 | INSTALL OCCUPANCY SENSORS | $2,011 | $6,725 | Implemented |
SF0376 # 04 Y:2009 | 04 | 2009 | AVOID FROST FORMATION ON EVAPORATORS | $2,865 | $9,600 | Implemented |
SF0376 # 05 Y:2009 | 05 | 2009 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $17,149 | $75,000 | Implemented |
SF0376 # 06 Y:2009 | 06 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,348 | $20,943 | Not Implemented |
GT0866 # 01 Y:2009 | 01 | 2009 | COMBINE UTILITY METERS | $26,664 | $9,750 | Not Implemented |
GT0866 # 02 Y:2009 | 02 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,311 | $800 | Implemented |
GT0866 # 03 Y:2009 | 03 | 2009 | USE SYNTHETIC LUBRICANT | $1,648 | $0 | Implemented |