Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,636
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0224 # 07 Y:2003 | 07 | 2003 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $26,018 | $50,000 | n/a |
MS0224 # 08 Y:2003 | 08 | 2003 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $12,652 | $0 | Not Implemented |
MS0224 # 09 Y:2003 | 09 | 2003 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $8,477 | $1,560 | Not Implemented |
MS0224 # 10 Y:2003 | 10 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,641 | $181 | Implemented |
MS0224 # 11 Y:2003 | 11 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,861 | $7,596 | Implemented |
MS0224 # 12 Y:2003 | 12 | 2003 | INSULATE BARE EQUIPMENT | $3,422 | $301 | Not Implemented |
MS0228 # 01 Y:2003 | 01 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,861 | $6,210 | Not Implemented |
MS0228 # 02 Y:2003 | 02 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,344 | $276 | Implemented |
MS0228 # 03 Y:2003 | 03 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,499 | $2,540 | Implemented |
MS0228 # 04 Y:2003 | 04 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,237 | $1,210 | Not Implemented |
MS0228 # 05 Y:2003 | 05 | 2003 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $323 | $0 | Implemented |
MS0228 # 06 Y:2003 | 06 | 2003 | INSULATE BARE EQUIPMENT | $90 | $157 | Not Implemented |
MS0227 # 01 Y:2003 | 01 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $19,277 | $0 | Not Implemented |
MS0227 # 02 Y:2003 | 02 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $9,782 | $5,356 | Implemented |
MS0227 # 03 Y:2003 | 03 | 2003 | USE RADIANT HEATER FOR SPOT HEATING | $2,347 | $400 | Implemented |
MS0227 # 04 Y:2003 | 04 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,123 | $477 | Implemented |
MS0227 # 05 Y:2003 | 05 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,437 | $742 | Not Implemented |
MS0227 # 06 Y:2003 | 06 | 2003 | INSTALL TIMERS AND/OR THERMOSTATS | $494 | $708 | Not Implemented |
MS0226 # 01 Y:2003 | 01 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $18,996 | $0 | Not Implemented |
MS0226 # 02 Y:2003 | 02 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,859 | $2,372 | Implemented |
MS0226 # 03 Y:2003 | 03 | 2003 | INSULATE BARE EQUIPMENT | $2,660 | $1,669 | Not Implemented |
MS0226 # 04 Y:2003 | 04 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,417 | $205 | Implemented |
MS0226 # 05 Y:2003 | 05 | 2003 | INSTALL TIMERS AND/OR THERMOSTATS | $886 | $591 | Not Implemented |
MS0225 # 01 Y:2003 | 01 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,764 | $670 | Implemented |
MS0225 # 02 Y:2003 | 02 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,290 | $4,667 | Implemented |