Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,615
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ME0147 # 04 Y:1995 | 04 | 1995 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,961 | $4,160 | Not Implemented |
ME0147 # 05 Y:1995 | 05 | 1995 | INSULATE BARE EQUIPMENT | $1,858 | $2,365 | Not Implemented |
ME0147 # 06 Y:1995 | 06 | 1995 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $1,311 | $370 | Not Implemented |
ME0147 # 07 Y:1995 | 07 | 1995 | INSTALL OCCUPANCY SENSORS | $1,260 | $300 | Not Implemented |
ME0147 # 08 Y:1995 | 08 | 1995 | PAY UTILITY BILLS ON TIME | $1,077 | $0 | Implemented |
ME0147 # 09 Y:1995 | 09 | 1995 | MINIMIZE WATER USAGE | $4,092 | $60,000 | Not Implemented |
ME0147 # 10 Y:1995 | 10 | 1995 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $6,122 | $650 | Implemented |
ME0147 # 11 Y:1995 | 11 | 1995 | MINIMIZE WATER USAGE | $727 | $440 | Implemented |
ME0146 # 01 Y:1995 | 01 | 1995 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $377 | $70,000 | Not Implemented |
ME0146 # 02 Y:1995 | 02 | 1995 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $1,276 | $154 | Not Implemented |
ME0146 # 03 Y:1995 | 03 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $383 | $500 | Implemented |
ME0146 # 04 Y:1995 | 04 | 1995 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $369 | $0 | Not Implemented |
ME0146 # 05 Y:1995 | 05 | 1995 | PAY UTILITY BILLS ON TIME | $231 | $0 | Not Implemented |
ME0144 # 01 Y:1994 | 01 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,667 | $960 | Not Implemented |
ME0144 # 02 Y:1994 | 02 | 1994 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,028 | $1,411 | Implemented |
ME0144 # 03 Y:1994 | 03 | 1994 | UPGRADE CONTROLS ON COMPRESSORS | $1,794 | $300 | Implemented |
ME0144 # 04 Y:1994 | 04 | 1994 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,455 | $2,758 | Implemented |
ME0144 # 05 Y:1994 | 05 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,177 | $733 | Not Implemented |
ME0144 # 06 Y:1994 | 06 | 1994 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $748 | $586 | Not Implemented |
ME0144 # 07 Y:1994 | 07 | 1994 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $606 | $150 | Not Implemented |
ME0145 # 01 Y:1994 | 01 | 1994 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,797 | $300 | Implemented |
ME0145 # 02 Y:1994 | 02 | 1994 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $1,471 | $800 | Not Implemented |
ME0145 # 03 Y:1994 | 03 | 1994 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $827 | $85 | Not Implemented |
ME0145 # 04 Y:1994 | 04 | 1994 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $642 | $550 | Not Implemented |
ME0143 # 01 Y:1994 | 01 | 1994 | PURCHASE EQUIPMENT INSTEAD OF LEASING | $8,107 | $28,250 | Not Implemented |