Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,980
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0973 # 06 Y:2017 | 06 | 2017 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $2,445 | $0 | Not Implemented |
UD0973 # 07 Y:2017 | 07 | 2017 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $58,900 | $97,666 | Not Implemented |
UD0973 # 08 Y:2017 | 08 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,858 | $0 | Not Implemented |
UD0973 # 09 Y:2017 | 09 | 2017 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,323 | $3,821 | Not Implemented |
UD0973 # 10 Y:2017 | 10 | 2017 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,232 | $10,000 | Not Implemented |
UD0973 # 11 Y:2017 | 11 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,134 | $44,200 | Not Implemented |
UD0972 # 01 Y:2017 | 01 | 2017 | COMBINE UTILITY METERS | $1,370 | $0 | Not Implemented |
UD0972 # 02 Y:2017 | 02 | 2017 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $5,897 | $0 | Implemented |
UD0972 # 03 Y:2017 | 03 | 2017 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,800 | $3,250 | Implemented |
UD0972 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,266 | $7,210 | Implemented |
UD0972 # 05 Y:2017 | 05 | 2017 | USE PHOTOCELL CONTROLS | $3,473 | $1,550 | Not Implemented |
UD0972 # 06 Y:2017 | 06 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,488 | $300 | Implemented |
UD0972 # 07 Y:2017 | 07 | 2017 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $454 | $1,400 | Not Implemented |
UD0971 # 01 Y:2017 | 01 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,580 | $0 | Implemented |
UD0971 # 02 Y:2017 | 02 | 2017 | USE MINIMUM STEAM OPERATING PRESSURE | $10,210 | $50 | Not Implemented |
UD0971 # 03 Y:2017 | 03 | 2017 | COVER OPEN TANKS | $8,336 | $2,760 | Not Implemented |
UD0971 # 04 Y:2017 | 04 | 2017 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $972 | $50 | Implemented |
UD0971 # 05 Y:2017 | 05 | 2017 | ADD AREA LIGHTING SWITCHES | $2,213 | $500 | Not Implemented |
UD0971 # 06 Y:2017 | 06 | 2017 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $400 | $681 | Not Implemented |
UD0971 # 07 Y:2017 | 07 | 2017 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,936 | $3,000 | Not Implemented |
UD0971 # 08 Y:2017 | 08 | 2017 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $51,180 | $3,650 | Not Implemented |
UD0971 # 09 Y:2017 | 09 | 2017 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $36,055 | $178,850 | Not Implemented |
UD0971 # 10 Y:2017 | 10 | 2017 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,985 | $22,000 | Not Implemented |
WV0551 # 01 Y:2017 | 01 | 2017 | INSTALL SENSORS TO DETECT AND AVOID JAMS | $12,866 | $7,175 | Not Implemented |
WV0551 # 02 Y:2017 | 02 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $9,068 | $42,825 | Not Implemented |