IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,130

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0410 # 04 Y:1993 04 1993 INSULATE BARE EQUIPMENT $1,730 $3,154 Not Implemented
KU0410 # 05 Y:1993 05 1993 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $810 $57 Not Implemented
KU0410 # 06 Y:1993 06 1993 INSTALL OCCUPANCY SENSORS $471 $1,650 Not Implemented
KU0410 # 07 Y:1993 07 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $380 $748 Not Implemented
KU0410 # 08 Y:1993 08 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $324 $201 Not Implemented
KU0410 # 09 Y:1993 09 1993 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $250 $260 Not Implemented
KU0410 # 10 Y:1993 10 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $239 $400 Not Implemented
AS0095 # 01 Y:1993 01 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $163 $200 Not Implemented
AS0095 # 02 Y:1993 02 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $432 $200 Implemented
AS0095 # 03 Y:1993 03 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $773 $506 Implemented
AS0095 # 04 Y:1993 04 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $614 $161 Not Implemented
AS0095 # 05 Y:1993 05 1993 INSTALL OCCUPANCY SENSORS $1,003 $603 Implemented
AS0095 # 06 Y:1993 06 1993 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT $1,567 $1,320 Not Implemented
AS0095 # 07 Y:1993 07 1993 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $191 $1,072 Not Implemented
AS0095 # 08 Y:1993 08 1993 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $2,540 $7,500 Not Implemented
AS0095 # 09 Y:1993 09 1993 INSULATE BARE EQUIPMENT $123 $279 Implemented
AS0095 # 10 Y:1993 10 1993 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $703 $500 Implemented
GT0499 # 01 Y:1993 01 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,700 $4,160 Not Implemented
GT0499 # 02 Y:1993 02 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,470 $18,550 Not Implemented
GT0499 # 03 Y:1993 03 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,950 $10,500 Implemented
GT0499 # 04 Y:1993 04 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $535 $900 Implemented
GT0499 # 05 Y:1993 05 1993 INSTALL OCCUPANCY SENSORS $2,260 $1,960 Not Implemented
GT0499 # 06 Y:1993 06 1993 USE PHOTOCELL CONTROLS $800 $700 Not Implemented
GT0499 # 07 Y:1993 07 1993 USE PHOTOCELL CONTROLS $130 $70 Not Implemented
GT0499 # 08 Y:1993 08 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $445 $370 Implemented