IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,032

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0495 # 09 Y:1998 09 1998 METER WASTE WATER $850 $100 Implemented
KU0495 # 10 Y:1998 10 1998 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $25,200 $33,030 Not Implemented
KU0495 # 11 Y:1998 11 1998 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $22,420 $24,760 Not Implemented
KU0495 # 01 Y:1998 01 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,700 $4,100 Not Implemented
KU0495 # 02 Y:1998 02 1998 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,680 $390 Implemented
KU0495 # 03 Y:1998 03 1998 USE SYNTHETIC LUBRICANT $3,080 $2,650 Implemented
KU0494 # 01 Y:1998 01 1998 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $20,790 $8,520 Implemented
KU0494 # 02 Y:1998 02 1998 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,030 $1,400 Implemented
KU0494 # 03 Y:1998 03 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,510 $19,700 Implemented
KU0494 # 04 Y:1998 04 1998 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,960 $2,390 Not Implemented
KU0494 # 05 Y:1998 05 1998 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $1,100 $1,250 Not Implemented
KU0494 # 06 Y:1998 06 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $510 $720 Implemented
KU0494 # 07 Y:1998 07 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $340 $880 Implemented
KU0494 # 08 Y:1998 08 1998 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES $4,260 $9,000 Not Implemented
KU0494 # 09 Y:1998 09 1998 REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL $30,350 $31,830 Implemented
KU0494 # 10 Y:1998 10 1998 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $8,330 $6,280 Not Implemented
KU0484 # 01 Y:1997 01 1997 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $9,050 $26,400 Not Implemented
KU0484 # 02 Y:1997 02 1997 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $7,770 $14,200 Implemented
KU0484 # 03 Y:1997 03 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,370 $24,290 Implemented
KU0484 # 04 Y:1997 04 1997 RECOVER WASTE HEAT FROM EQUIPMENT $5,410 $640 Not Implemented
KU0484 # 05 Y:1997 05 1997 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,270 $1,350 Not Implemented
KU0484 # 06 Y:1997 06 1997 INSTALL OCCUPANCY SENSORS $320 $400 Not Implemented
KU0484 # 07 Y:1997 07 1997 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $7,660 $0 Implemented
KU0484 # 08 Y:1997 08 1997 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES $310 $1,050 Not Implemented
KU0484 # 09 Y:1997 09 1997 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $18,220 $4,200 Implemented