Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
146,354
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0092 # 02 Y:1983 | 02 | 1983 | INSTALL STORM WINDOWS AND DOORS | $4,277 | $8,800 | Not Implemented |
UD0092 # 03 Y:1983 | 03 | 1983 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,757 | $250 | Not Implemented |
UD0092 # 04 Y:1983 | 04 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,590 | $1,300 | Not Implemented |
UD0093 # 01 Y:1983 | 01 | 1983 | BURN WOOD BY-PRODUCTS FOR HEAT | $33,271 | $53,040 | Not Implemented |
UD0093 # 02 Y:1983 | 02 | 1983 | INSTALL STORM WINDOWS AND DOORS | $12,137 | $7,918 | Implemented |
UD0093 # 03 Y:1983 | 03 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,042 | $5,758 | Implemented |
UD0093 # 04 Y:1983 | 04 | 1983 | RECOVER WASTE HEAT FROM EQUIPMENT | $629 | $500 | Implemented |
UD0094 # 01 Y:1983 | 01 | 1983 | TURN OFF EQUIPMENT WHEN NOT IN USE | $26,749 | $55,800 | Not Implemented |
UD0094 # 02 Y:1983 | 02 | 1983 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $25,138 | $11,160 | Implemented |
UD0094 # 03 Y:1983 | 03 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,709 | $1,561 | Not Implemented |
UD0094 # 04 Y:1983 | 04 | 1983 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $703 | $110 | Not Implemented |
UD0094 # 05 Y:1983 | 05 | 1983 | INSTALL TIMERS AND/OR THERMOSTATS | $689 | $1,200 | Not Implemented |
GT0192 # 01 Y:1983 | 01 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,025 | $2,450 | Not Implemented |
GT0192 # 02 Y:1983 | 02 | 1983 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $537 | $800 | Not Implemented |
GT0192 # 03 Y:1983 | 03 | 1983 | INSTALL / REPAIR INSULATION ON STEAM LINES | $130 | $80 | Not Implemented |
GT0199 # 01 Y:1983 | 01 | 1983 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $4,320 | $6,100 | Implemented |
GT0199 # 02 Y:1983 | 02 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,149 | $2,491 | Not Implemented |
GT0199 # 03 Y:1983 | 03 | 1983 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $130 | $75 | Implemented |
KU0097 # 01 Y:1983 | 01 | 1983 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $12,636 | $13,000 | Not Implemented |
KU0097 # 02 Y:1983 | 02 | 1983 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $10,812 | $8,500 | Not Implemented |
KU0097 # 03 Y:1983 | 03 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,389 | $4,629 | Not Implemented |
KU0097 # 04 Y:1983 | 04 | 1983 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,608 | $132 | Implemented |
KU0097 # 05 Y:1983 | 05 | 1983 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $2,533 | $2,500 | Not Implemented |
KU0097 # 06 Y:1983 | 06 | 1983 | OPTIMIZE PLANT POWER FACTOR | $1,494 | $2,800 | Not Implemented |
KU0097 # 07 Y:1983 | 07 | 1983 | INSTALL TIMERS AND/OR THERMOSTATS | $727 | $200 | Implemented |