IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,032

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0463 # 03 Y:1996 03 1996 INSTALL OCCUPANCY SENSORS $1,237 $1,200 Not Implemented
KU0463 # 04 Y:1996 04 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $936 $2,112 Implemented
KU0463 # 05 Y:1996 05 1996 ADJUST BURNERS FOR EFFICIENT OPERATION $633 $1,000 Implemented
KU0463 # 06 Y:1996 06 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $482 $375 Not Implemented
KU0461 # 01 Y:1996 01 1996 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $89,682 $1,500 Implemented
KU0461 # 02 Y:1996 02 1996 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,630 $1,000 Implemented
KU0461 # 03 Y:1996 03 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,413 $2,270 Implemented
KU0461 # 04 Y:1996 04 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,403 $4,880 Implemented
KU0461 # 05 Y:1996 05 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,146 $3,783 Implemented
KU0461 # 06 Y:1996 06 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $747 $707 Implemented
KU0461 # 07 Y:1996 07 1996 INSTALL OCCUPANCY SENSORS $530 $250 Not Implemented
KU0461 # 08 Y:1996 08 1996 USE SYNTHETIC LUBRICANT $409 $270 Implemented
KU0460 # 01 Y:1996 01 1996 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $38,846 $2,500 Implemented
KU0460 # 02 Y:1996 02 1996 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $6,108 $15,150 Implemented
KU0460 # 03 Y:1996 03 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,741 $20,119 Not Implemented
KU0460 # 04 Y:1996 04 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,386 $5,807 Not Implemented
KU0460 # 05 Y:1996 05 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,935 $375 Not Implemented
KU0460 # 06 Y:1996 06 1996 INSTALL OCCUPANCY SENSORS $1,272 $850 Not Implemented
KU0460 # 07 Y:1996 07 1996 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $183 $0 Not Implemented
OK0498 # 01 Y:1996 01 1996 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,692 $3,200 Implemented
OK0498 # 02 Y:1996 02 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,469 $1,648 Implemented
OK0498 # 03 Y:1996 03 1996 RECOVER WASTE HEAT FROM EQUIPMENT $4,649 $1,399 Not Implemented
OK0498 # 04 Y:1996 04 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,295 $4,770 Implemented
OK0498 # 05 Y:1996 05 1996 INSTALL OCCUPANCY SENSORS $120 $366 Not Implemented
OK0498 # 06 Y:1996 06 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $17,199 $23,287 Implemented