IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,302

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0358 # 12 Y:2008 12 2008 TURN OFF EQUIPMENT WHEN NOT IN USE $606 $2,130 Implemented
SF0358 # 13 Y:2008 13 2008 INSULATE BARE EQUIPMENT $2,327 $8,208 Implemented
SF0358 # 14 Y:2008 14 2008 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $14,884 $150,000 Not Implemented
SF0358 # 15 Y:2008 15 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,657 $97,375 Not Implemented
SF0358 # 16 Y:2008 16 2008 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $6,581 $35,183 Not Implemented
GT0851 # 01 Y:2008 01 2008 INCREASE AMOUNT OF CONDENSATE RETURNED $48,953 $8,350 Not Implemented
GT0851 # 02 Y:2008 02 2008 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $12,800 $0 Not Implemented
GT0851 # 03 Y:2008 03 2008 USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE $15,410 $0 Not Implemented
GT0851 # 04 Y:2008 04 2008 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $18,784 $450 Not Implemented
GT0851 # 05 Y:2008 05 2008 REPAIR AND ELIMINATE STEAM LEAKS $13,289 $2,260 Not Implemented
GT0851 # 06 Y:2008 06 2008 INSTALL / REPAIR INSULATION ON STEAM LINES $2,838 $1,832 Not Implemented
GT0851 # 07 Y:2008 07 2008 MINIMIZE WATER USAGE $20,751 $3,000 Not Implemented
GT0851 # 08 Y:2008 08 2008 SUBSTITUTE HOT PROCESS FLUIDS FOR STEAM $10,080 $32,550 Not Implemented
GT0851 # 09 Y:2008 09 2008 RECOVER WASTE HEAT FROM EQUIPMENT $12,485 $24,000 Not Implemented
GT0851 # 10 Y:2008 10 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,770 $5,110 Not Implemented
IA0426 # 01 Y:2008 01 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $17,200 $10,307 Implemented
IA0426 # 02 Y:2008 02 2008 INSTALL OCCUPANCY SENSORS $678 $847 Implemented
IA0426 # 03 Y:2008 03 2008 INSTALL SPECTRAL REFLECTORS / DELAMP $3,565 $225 Implemented
IA0426 # 04 Y:2008 04 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,748 $2,450 Implemented
IA0426 # 05 Y:2008 05 2008 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $4,526 $30 Not Implemented
IA0426 # 06 Y:2008 06 2008 PAY UTILITY BILLS ON TIME $16,112 $0 Implemented
IA0426 # 07 Y:2008 07 2008 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $4,743 $185 Implemented
IA0426 # 08 Y:2008 08 2008 VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE $7,288 $3,550 Not Implemented
IA0426 # 09 Y:2008 09 2008 VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE $4,110 $10,000 Not Implemented
IA0426 # 10 Y:2008 10 2008 OPTIMIZE PLANT POWER FACTOR $64,666 $43,320 Not Implemented