Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,130
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0512 # 01 Y:1993 | 01 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $18,800 | $61,520 | Implemented |
GT0512 # 02 Y:1993 | 02 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,220 | $0 | Not Implemented |
GT0512 # 03 Y:1993 | 03 | 1993 | INSULATE BARE EQUIPMENT | $830 | $2,270 | Implemented |
GT0512 # 04 Y:1993 | 04 | 1993 | INSULATE BARE EQUIPMENT | $410 | $520 | Implemented |
GT0512 # 05 Y:1993 | 05 | 1993 | INCREASE AMOUNT OF CONDENSATE RETURNED | $470 | $1,000 | Implemented |
GT0512 # 06 Y:1993 | 06 | 1993 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $27,400 | $38,000 | Not Implemented |
GT0512 # 07 Y:1993 | 07 | 1993 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $530 | $500 | Implemented |
KU0419 # 01 Y:1993 | 01 | 1993 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $167,541 | $640,000 | Not Implemented |
KU0419 # 02 Y:1993 | 02 | 1993 | INSULATE BARE EQUIPMENT | $4,443 | $2,405 | Not Implemented |
KU0419 # 03 Y:1993 | 03 | 1993 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $10,041 | $15,400 | Not Implemented |
KU0419 # 04 Y:1993 | 04 | 1993 | REPAIR AND ELIMINATE STEAM LEAKS | $3,075 | $750 | Implemented |
KU0419 # 05 Y:1993 | 05 | 1993 | INSULATE BARE EQUIPMENT | $2,124 | $5,376 | Not Implemented |
KU0419 # 06 Y:1993 | 06 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,907 | $201 | Not Implemented |
KU0419 # 07 Y:1993 | 07 | 1993 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,428 | $1,386 | Implemented |
AR0012 # 01 Y:1993 | 01 | 1993 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,665 | $1,170 | Implemented |
AR0012 # 02 Y:1993 | 02 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,387 | $400 | Implemented |
AR0012 # 03 Y:1993 | 03 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $949 | $720 | Implemented |
AR0012 # 04 Y:1993 | 04 | 1993 | OVERLAP CUSTODIAL SERVICES WITH NORMAL DAY HOURS | $1,373 | $100 | Not Implemented |
AR0012 # 05 Y:1993 | 05 | 1993 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $23,430 | $23,250 | Not Implemented |
AR0012 # 06 Y:1993 | 06 | 1993 | INSULATE BARE EQUIPMENT | $1,684 | $330 | Not Implemented |
CO0290 # 01 Y:1993 | 01 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,960 | $6,140 | Implemented |
CO0290 # 02 Y:1993 | 02 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $12,920 | $16,060 | Implemented |
CO0290 # 03 Y:1993 | 03 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,750 | $30,180 | Implemented |
CO0290 # 04 Y:1993 | 04 | 1993 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $3,580 | $5,000 | Implemented |
CO0290 # 05 Y:1993 | 05 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,350 | $2,500 | Not Implemented |