IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,417

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0175 # 02 Y:1990 02 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $385 $0 Implemented
MA0175 # 03 Y:1990 03 1990 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,043 $234 Not Implemented
MA0175 # 04 Y:1990 04 1990 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,216 $5,256 Implemented
MA0175 # 05 Y:1990 05 1990 OPTIMIZE PLANT POWER FACTOR $1,528 $2,710 Implemented
MA0176 # 01 Y:1990 01 1990 INSTALL TIMERS AND/OR THERMOSTATS $444 $1,000 Implemented
MA0176 # 02 Y:1990 02 1990 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,404 $2,000 Implemented
MA0176 # 03 Y:1990 03 1990 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $1,258 $3,500 Not Implemented
MA0176 # 04 Y:1990 04 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $799 $101 Implemented
MA0176 # 05 Y:1990 05 1990 RECOVER WASTE HEAT FROM EQUIPMENT $2,776 $2,000 Not Implemented
MA0176 # 06 Y:1990 06 1990 USE DIRECT AIR SUPPLY TO EXHAUST HOODS $1,909 $2,000 Implemented
MA0176 # 07 Y:1990 07 1990 INSTALL SET-BACK TIMERS $106 $200 Implemented
OR0082 # 01 Y:1990 01 1990 INSTALL SET-BACK TIMERS $4,474 $0 Implemented
OR0082 # 02 Y:1990 02 1990 RECOVER WASTE HEAT FROM EQUIPMENT $2,608 $75 Implemented
OR0082 # 03 Y:1990 03 1990 MINIMIZE WATER USAGE $870 $75 Implemented
OR0082 # 04 Y:1990 04 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $382 $240 Implemented
OR0082 # 05 Y:1990 05 1990 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,055 $500 Implemented
OR0082 # 06 Y:1990 06 1990 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $103 $182 Implemented
OR0082 # 07 Y:1990 07 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $498 $700 Implemented
OR0082 # 08 Y:1990 08 1990 OPTIMIZE PLANT POWER FACTOR $161 $450 Not Implemented
OR0083 # 01 Y:1990 01 1990 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,850 $0 Implemented
OR0083 # 02 Y:1990 02 1990 OPTIMIZE PLANT POWER FACTOR $20,444 $16,800 Not Implemented
OR0083 # 03 Y:1990 03 1990 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,646 $5,000 Implemented
OR0083 # 04 Y:1990 04 1990 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $24,439 $46,216 Not Implemented
OR0083 # 05 Y:1990 05 1990 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $190 $490 Not Implemented
UD0311 # 01 Y:1990 01 1990 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $5,733 $2,400 Implemented