Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,597
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0548 # 01 Y:2017 | 01 | 2017 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $9,343 | $2,478 | Not Implemented |
WV0548 # 02 Y:2017 | 02 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,922 | $41,392 | Implemented |
WV0548 # 03 Y:2017 | 03 | 2017 | INSTALL SENSORS TO DETECT AND AVOID JAMS | $6,579 | $1,611 | Not Implemented |
WV0548 # 04 Y:2017 | 04 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,331 | $0 | Implemented |
WV0548 # 05 Y:2017 | 05 | 2017 | MINIMIZE WATER USAGE | $4,164 | $750 | Not Implemented |
WV0548 # 06 Y:2017 | 06 | 2017 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $3,443 | $1,000 | Implemented |
WV0548 # 07 Y:2017 | 07 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,545 | $8,388 | Implemented |
WV0548 # 08 Y:2017 | 08 | 2017 | UPGRADE CONTROLS ON COMPRESSORS | $2,479 | $10,000 | Not Implemented |
WV0548 # 09 Y:2017 | 09 | 2017 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,157 | $3,278 | Not Implemented |
WV0548 # 10 Y:2017 | 10 | 2017 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,140 | $1,058 | Not Implemented |
WV0548 # 11 Y:2017 | 11 | 2017 | DEVELOP A REPAIR/REPLACE POLICY | $1,024 | $699 | Implemented |
WV0548 # 12 Y:2017 | 12 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $863 | $431 | Implemented |
WV0548 # 13 Y:2017 | 13 | 2017 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $260 | $850 | Implemented |
OK0969 # 01 Y:2017 | 01 | 2017 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $23,730 | $42,000 | Not Implemented |
OK0969 # 02 Y:2017 | 02 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $29,000 | $48,139 | Implemented |
OK0969 # 03 Y:2017 | 03 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $532 | $4,727 | Not Implemented |
OK0969 # 04 Y:2017 | 04 | 2017 | REPAIR AND ELIMINATE STEAM LEAKS | $12,697 | $2,712 | Not Implemented |
OK0969 # 05 Y:2017 | 05 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $21,138 | $23,262 | Not Implemented |
OK0969 # 06 Y:2017 | 06 | 2017 | OPTIMIZE PLANT POWER FACTOR | $2,384 | $16,995 | Not Implemented |
OK0969 # 07 Y:2017 | 07 | 2017 | PAY UTILITY BILLS ON TIME | $4,330 | $0 | Implemented |
OK0969 # 08 Y:2017 | 08 | 2017 | INSTALL SET-BACK TIMERS | $396 | $148 | Not Implemented |
MA0775 # 01 Y:2017 | 01 | 2017 | OPTIMIZE PLANT POWER FACTOR | $28,320 | $16,929 | Not Implemented |
MA0775 # 02 Y:2017 | 02 | 2017 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $20,697 | $100 | Implemented |
MA0775 # 03 Y:2017 | 03 | 2017 | AIR CONDITION ONLY SPACE NECESSARY | $13,365 | $7,900 | Not Implemented |
MA0775 # 04 Y:2017 | 04 | 2017 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $10,486 | $21,000 | Not Implemented |