Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,500
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OD0063 # 02 Y:1996 | 02 | 1996 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $336 | $88 | Implemented |
OD0063 # 03 Y:1996 | 03 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,273 | $1,444 | Implemented |
OD0063 # 04 Y:1996 | 04 | 1996 | USE SYNTHETIC LUBRICANT | $582 | $325 | Implemented |
OD0063 # 05 Y:1996 | 05 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $1,423 | $0 | Implemented |
OD0062 # 01 Y:1996 | 01 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,072 | $2,400 | Implemented |
OD0062 # 02 Y:1996 | 02 | 1996 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $1,584 | $3,850 | Not Implemented |
OD0062 # 03 Y:1996 | 03 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,718 | $2,400 | Not Implemented |
OD0062 # 04 Y:1996 | 04 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $2,171 | $780 | Implemented |
OD0062 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,512 | $8,748 | Implemented |
OD0062 # 06 Y:1996 | 06 | 1996 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $25,196 | $0 | Not Implemented |
OD0057 # 01 Y:1996 | 01 | 1996 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $6,833 | $500 | Implemented |
OD0057 # 02 Y:1996 | 02 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,120 | $600 | Implemented |
OD0057 # 03 Y:1996 | 03 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,630 | $1,950 | Implemented |
OD0057 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,768 | $430 | Implemented |
OD0057 # 05 Y:1996 | 05 | 1996 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,639 | $4,232 | Not Implemented |
OD0057 # 06 Y:1996 | 06 | 1996 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $751 | $200 | Not Implemented |
OD0061 # 01 Y:1996 | 01 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $189 | $160 | Not Implemented |
OD0061 # 02 Y:1996 | 02 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $337 | $270 | Not Implemented |
OD0061 # 03 Y:1996 | 03 | 1996 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $11,625 | $5,634 | Not Implemented |
OD0061 # 04 Y:1996 | 04 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $161 | $485 | Not Implemented |
OD0061 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,584 | $6,110 | Not Implemented |
OD0061 # 06 Y:1996 | 06 | 1996 | INSTALL OCCUPANCY SENSORS | $408 | $689 | Not Implemented |
OD0061 # 07 Y:1996 | 07 | 1996 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $46 | $0 | Not Implemented |
OD0061 # 08 Y:1996 | 08 | 1996 | CONVERT TO AQUEOUS CLEANING SYSTEM | $3,004 | $5,050 | Not Implemented |
OD0059 # 01 Y:1996 | 01 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,899 | $1,600 | Not Implemented |