Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,175
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AT0067 # 01 Y:1987 | 01 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,141 | $481 | Implemented |
AT0067 # 02 Y:1987 | 02 | 1987 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $580 | $1,500 | Not Implemented |
AT0067 # 03 Y:1987 | 03 | 1987 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $1,199 | $1,000 | Implemented |
AT0067 # 04 Y:1987 | 04 | 1987 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $174 | $50 | Implemented |
AT0067 # 05 Y:1987 | 05 | 1987 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $155 | $0 | Implemented |
AT0068 # 01 Y:1987 | 01 | 1987 | INSTALL SET-BACK TIMERS | $538 | $485 | Implemented |
AT0068 # 02 Y:1987 | 02 | 1987 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $231 | $303 | Implemented |
AT0068 # 03 Y:1987 | 03 | 1987 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $954 | $0 | Implemented |
AT0068 # 04 Y:1987 | 04 | 1987 | IMPROVE LUBRICATION PRACTICES | $513 | $0 | Implemented |
AT0068 # 05 Y:1987 | 05 | 1987 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $83 | $150 | Implemented |
AT0068 # 06 Y:1987 | 06 | 1987 | USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING | $1,461 | $4,000 | Implemented |
KU0216 # 01 Y:1987 | 01 | 1987 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $21,533 | $20,000 | Implemented |
KU0216 # 02 Y:1987 | 02 | 1987 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $13,014 | $15,000 | Not Implemented |
KU0216 # 03 Y:1987 | 03 | 1987 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $6,934 | $9,000 | Not Implemented |
KU0216 # 04 Y:1987 | 04 | 1987 | INSTALL SET-BACK TIMERS | $2,429 | $683 | Implemented |
KU0216 # 05 Y:1987 | 05 | 1987 | IMPROVE LUBRICATION PRACTICES | $2,386 | $2,250 | Implemented |
KU0216 # 06 Y:1987 | 06 | 1987 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,562 | $0 | Implemented |
KU0216 # 07 Y:1987 | 07 | 1987 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,128 | $200 | Not Implemented |
UD0227 # 01 Y:1987 | 01 | 1987 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $26,035 | $30,000 | Implemented |
UD0227 # 02 Y:1987 | 02 | 1987 | OPTIMIZE PLANT POWER FACTOR | $4,712 | $12,000 | Implemented |
UD0227 # 03 Y:1987 | 03 | 1987 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $1,245 | $0 | Not Implemented |
UD0227 # 04 Y:1987 | 04 | 1987 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $534 | $6,000 | Implemented |
UD0227 # 05 Y:1987 | 05 | 1987 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,752 | $0 | Not Implemented |
UD0228 # 01 Y:1987 | 01 | 1987 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $8,352 | $13,000 | Implemented |
UD0228 # 02 Y:1987 | 02 | 1987 | REDESIGN PROCESS | $734 | $200 | Not Implemented |