Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Dayton
Assessment Year 1987
Principal Product WELDING WIRES & FLUXES
NAICS n/a
SIC 3398 - Metal Heat Treating
Sales $10,000,000-$50,000,000
# of Employees 200
Plant Area (Sq.Ft.) 0
Annual Production 3,600,000 Pounds
Production Hrs. Annual 6,000
Location (State) OH
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $369,892 5,623,095 kWh $0.07
Natural Gas $54,667 10,639 MMBtu $5.14
TOTAL ENERGY COSTS $424,559
RECOMMENDED SAVINGS* $38,278 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $31,281
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$26,035
Cost:
$30,000
$32,616 577,081 $(-6,581) (-1,266) - - $32,616
577,081
kWh
$(-6,581)
(-1,266)
MMBtu
-
-
$
02: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$4,712
Cost:
$12,000
$4,712 - - - - - $4,712
-
kWh
-
-
MMBtu
-
-
$
03: 2.6221 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY Savings:
$1,245
Cost:
-
$1,844 53,634 $(-599) (-122) - - $1,844
53,634
kWh
$(-599)
(-122)
MMBtu
-
-
$
04: 2.7133 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE Savings:
$534
Cost:
$6,000
$422 12,309 - - $112 - $422
12,309
kWh
-
-
MMBtu
$112
-
$
05: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$5,752
Cost:
-
$7,152 - - - $(-1,400) - $7,152
-
kWh
-
-
MMBtu
$(-1,400)
-
$
TOTAL RECOMMENDED Savings:
$38,278
Cost:
$48,000
$46,746 643,024 $(-7,180) (-1,388) $(-1,288) - $46,746
643,024
kWh
$(-7,180)
(-1,388)
MMBtu
$(-1,288)
-
$
TOTAL IMPLEMENTED Savings:
$31,281
Cost:
$48,000
$37,750 589,390 $(-6,581) (-1,266) $112 - $37,750
589,390
kWh
$(-6,581)
(-1,266)
MMBtu
$112
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes