Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
273
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0036 # 04 Y:1982 | 04 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,547 | $675 | Implemented |
OK0041 # 01 Y:1982 | 01 | 1982 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $662 | $1,998 | Not Implemented |
OK0041 # 02 Y:1982 | 02 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $177 | $1,054 | Not Implemented |
OK0041 # 03 Y:1982 | 03 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $41 | $86 | Not Implemented |
OK0041 # 04 Y:1982 | 04 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $116 | $320 | Not Implemented |
OK0041 # 05 Y:1982 | 05 | 1982 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,285 | $200 | Not Implemented |
OK0042 # 01 Y:1982 | 01 | 1982 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,978 | $0 | Not Implemented |
OK0042 # 02 Y:1982 | 02 | 1982 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $723 | $44 | Not Implemented |
OK0042 # 03 Y:1982 | 03 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $35 | $14 | Not Implemented |
OK0042 # 04 Y:1982 | 04 | 1982 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,698 | $728 | Not Implemented |
OK0042 # 05 Y:1982 | 05 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $330 | $1,250 | Not Implemented |
OK0043 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $58 | $34 | Implemented |
OK0043 # 02 Y:1982 | 02 | 1982 | INSTALL TURBULATORS | $137 | $670 | Not Implemented |
OK0043 # 03 Y:1982 | 03 | 1982 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $33 | $600 | Implemented |
OK0043 # 04 Y:1982 | 04 | 1982 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,200 | $210 | Implemented |
OK0043 # 05 Y:1982 | 05 | 1982 | HEAT WATER WITH EXHAUST HEAT | $453 | $1,384 | Not Implemented |
OK0049 # 01 Y:1982 | 01 | 1982 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $259 | $450 | Not Implemented |
OK0049 # 02 Y:1982 | 02 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $443 | $234 | Implemented |
OK0049 # 03 Y:1982 | 03 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $400 | $3,576 | Not Implemented |
OK0049 # 04 Y:1982 | 04 | 1982 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $7 | $60 | Not Implemented |
OK0049 # 05 Y:1982 | 05 | 1982 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $39 | $75 | Not Implemented |
OK0026 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $165 | $48 | Not Implemented |
OK0026 # 02 Y:1982 | 02 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $87 | $58 | Not Implemented |
OK0026 # 03 Y:1982 | 03 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $240 | $9 | Not Implemented |
OK0026 # 04 Y:1982 | 04 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $167 | $300 | Not Implemented |