Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
8,704
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0169 # 06 Y:2010 | 06 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,108 | $1,339 | Not Implemented |
IC0169 # 07 Y:2010 | 07 | 2010 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $538 | $0 | Not Implemented |
IC0169 # 08 Y:2010 | 08 | 2010 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $5,189 | $1,632 | Not Implemented |
IC0169 # 09 Y:2010 | 09 | 2010 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $4,975 | $4,551 | Not Implemented |
IC0169 # 10 Y:2010 | 10 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $28,097 | $1,670 | Not Implemented |
IC0169 # 11 Y:2010 | 11 | 2010 | INSTALL / REPAIR INSULATION ON STEAM LINES | $318 | $613 | Not Implemented |
IC0169 # 12 Y:2010 | 12 | 2010 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $5,403 | $2,401 | Not Implemented |
IC0169 # 13 Y:2010 | 13 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,074 | $1,265 | Not Implemented |
IC0169 # 14 Y:2010 | 14 | 2010 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $124 | $600 | Not Implemented |
IC0169 # 15 Y:2010 | 15 | 2010 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $245 | $0 | Not Implemented |
BD0373 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,308 | $48,175 | Not Implemented |
BD0373 # 02 Y:2010 | 02 | 2010 | INSTALL OCCUPANCY SENSORS | $2,326 | $2,100 | Not Implemented |
BD0373 # 03 Y:2010 | 03 | 2010 | USE PHOTOCELL CONTROLS | $1,390 | $3,600 | Not Implemented |
BD0373 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,113 | $800 | Not Implemented |
BD0373 # 05 Y:2010 | 05 | 2010 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,349 | $2,000 | Not Implemented |
BD0373 # 06 Y:2010 | 06 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $40,661 | $54,000 | Not Implemented |
BD0373 # 07 Y:2010 | 07 | 2010 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $2,064 | $3,000 | Not Implemented |
BD0372 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $31,215 | $108,017 | Not Implemented |
BD0372 # 02 Y:2010 | 02 | 2010 | INSTALL OCCUPANCY SENSORS | $7,103 | $5,475 | Not Implemented |
BD0372 # 03 Y:2010 | 03 | 2010 | DISCONNECT BALLASTS | $1,532 | $490 | Not Implemented |
BD0372 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,030 | $800 | Not Implemented |
BD0372 # 05 Y:2010 | 05 | 2010 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $7,363 | $4,400 | Not Implemented |
BD0372 # 06 Y:2010 | 06 | 2010 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,914 | $5,000 | Implemented |
BD0372 # 07 Y:2010 | 07 | 2010 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $55,206 | $9,400 | Not Implemented |
BD0370 # 01 Y:2010 | 01 | 2010 | INSTALL SKYLIGHTS | $9,511 | $30,250 | Not Implemented |