Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,032
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0364 # 09 Y:1992 | 09 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,372 | $3,990 | Not Implemented |
KU0362 # 01 Y:1992 | 01 | 1992 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,961 | $120 | Not Implemented |
KU0362 # 02 Y:1992 | 02 | 1992 | RECOVER WASTE HEAT FROM EQUIPMENT | $829 | $1,327 | Implemented |
KU0362 # 03 Y:1992 | 03 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $801 | $250 | Not Implemented |
KU0362 # 04 Y:1992 | 04 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $401 | $15 | Implemented |
KU0362 # 05 Y:1992 | 05 | 1992 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,755 | $5,200 | Not Implemented |
KU0362 # 06 Y:1992 | 06 | 1992 | INSTALL TURBULATORS | $828 | $1,087 | Not Implemented |
KU0362 # 07 Y:1992 | 07 | 1992 | ADD AIR SHIELDS TO TRUCKS TO INCREASE FUEL MILEAGE | $1,247 | $1,000 | Implemented |
KU0362 # 08 Y:1992 | 08 | 1992 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $988 | $244 | Implemented |
KU0362 # 09 Y:1992 | 09 | 1992 | REPAIR AND ELIMINATE STEAM LEAKS | $869 | $600 | Implemented |
KU0362 # 10 Y:1992 | 10 | 1992 | INSTALL / REPAIR INSULATION ON STEAM LINES | $633 | $502 | Implemented |
KU0362 # 11 Y:1992 | 11 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $422 | $0 | Not Implemented |
KU0361 # 04 Y:1992 | 04 | 1992 | KEEP BOILER TUBES CLEAN | $275 | $450 | Implemented |
KU0361 # 05 Y:1992 | 05 | 1992 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $408 | $480 | Implemented |
KU0361 # 06 Y:1992 | 06 | 1992 | INSTALL SET-BACK TIMERS | $288 | $330 | Not Implemented |
KU0361 # 07 Y:1992 | 07 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $474 | $350 | Implemented |
KU0361 # 08 Y:1992 | 08 | 1992 | RECOVER WASTE HEAT FROM EQUIPMENT | $832 | $500 | Implemented |
KU0361 # 01 Y:1992 | 01 | 1992 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $1,475 | $6,000 | Not Implemented |
KU0361 # 02 Y:1992 | 02 | 1992 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $701 | $0 | Implemented |
KU0361 # 03 Y:1992 | 03 | 1992 | RECOVER WASTE HEAT FROM EQUIPMENT | $375 | $520 | Implemented |
OK0361 # 01 Y:1991 | 01 | 1991 | RECOVER WASTE HEAT FROM EQUIPMENT | $307 | $403 | Not Implemented |
OK0361 # 02 Y:1991 | 02 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,285 | $0 | Not Implemented |
OK0361 # 03 Y:1991 | 03 | 1991 | INSTALL TIMERS AND/OR THERMOSTATS | $3,012 | $1,050 | Not Implemented |
OK0361 # 04 Y:1991 | 04 | 1991 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $10,521 | $13,526 | Not Implemented |
OK0361 # 05 Y:1991 | 05 | 1991 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,198 | $107 | Not Implemented |