Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Univ. of Kansas
Assessment Year 1992
Principal Product HAMBURGER BUNS
NAICS n/a
SIC 2051 - Bread, Cake, And Related Products
Sales $10,000,000-$50,000,000
# of Employees 45
Plant Area (Sq.Ft.) 0
Annual Production 16,000,000 Pieces
Production Hrs. Annual 6,240
Location (State) KS
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $246,489 4,580,598 kWh $0.05
Natural Gas $86,620 20,243 MMBtu $4.28
TOTAL ENERGY COSTS $333,109
RECOMMENDED SAVINGS* $38,848 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $11,263
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.2621 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE Savings:
$24,869
Cost:
$10,000
$24,869 462,192 - - - - $24,869
462,192
kWh
-
-
MMBtu
-
-
$
02: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$6,102
Cost:
$2,000
$6,102 113,423 - - - - $6,102
113,423
kWh
-
-
MMBtu
-
-
$
03: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$4,116
Cost:
$2,408
$4,116 - - - - - $4,116
-
kWh
-
-
MMBtu
-
-
$
04: 2.6232 INSTALL SET-BACK TIMERS Savings:
$568
Cost:
$400
$568 10,551 - - - - $568
10,551
kWh
-
-
MMBtu
-
-
$
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$484
Cost:
$771
$484 4,982 - - - - $484
4,982
kWh
-
-
MMBtu
-
-
$
06: 2.1232 KEEP BOILER TUBES CLEAN Savings:
$561
Cost:
$135
- - $561 131 - - -
-
kWh
$561
131
MMBtu
-
-
$
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$177
Cost:
-
$227 4,103 - - $(-50) - $227
4,103
kWh
-
-
MMBtu
$(-50)
-
$
08: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$599
Cost:
$150
$599 11,137 - - - - $599
11,137
kWh
-
-
MMBtu
-
-
$
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,372
Cost:
$3,990
$1,372 25,498 - - - - $1,372
25,498
kWh
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$38,848
Cost:
$19,854
$38,337 631,886 $561 131 $(-50) - $38,337
631,886
kWh
$561
131
MMBtu
$(-50)
-
$
TOTAL IMPLEMENTED Savings:
$11,263
Cost:
$5,314
$10,702 118,405 $561 131 - - $10,702
118,405
kWh
$561
131
MMBtu
-
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes