Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,091
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0214 # 05 Y:1991 | 05 | 1991 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,050 | $25,000 | Not Implemented |
CO0214 # 06 Y:1991 | 06 | 1991 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $950 | $6,500 | Not Implemented |
ND0001 # 01 Y:1991 | 01 | 1991 | OPTIMIZE PLANT POWER FACTOR | $17,472 | $19,313 | Implemented |
ND0001 # 02 Y:1991 | 02 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $840 | $1,000 | Implemented |
ND0001 # 03 Y:1991 | 03 | 1991 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $107 | $400 | Implemented |
ND0001 # 04 Y:1991 | 04 | 1991 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $240 | $200 | Implemented |
ND0001 # 05 Y:1991 | 05 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $527 | $2,287 | Implemented |
ND0001 # 06 Y:1991 | 06 | 1991 | DISCONNECT BALLASTS | $60 | $200 | Implemented |
OK0341 # 01 Y:1991 | 01 | 1991 | INSTALL TIMERS AND/OR THERMOSTATS | $355 | $245 | Implemented |
OK0341 # 02 Y:1991 | 02 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,004 | $6,200 | Implemented |
OK0341 # 03 Y:1991 | 03 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,241 | $791 | Implemented |
OK0341 # 04 Y:1991 | 04 | 1991 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $14,080 | $38,500 | Implemented |
OK0341 # 05 Y:1991 | 05 | 1991 | INSTALL TIMERS AND/OR THERMOSTATS | $1,481 | $1,800 | Implemented |
OK0341 # 06 Y:1991 | 06 | 1991 | INSTALL SET-BACK TIMERS | $19,001 | $13,510 | Implemented |
OK0341 # 07 Y:1991 | 07 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $846 | $1,336 | Implemented |
OK0341 # 08 Y:1991 | 08 | 1991 | REPAIR AND ELIMINATE STEAM LEAKS | $443 | $740 | Implemented |
OK0341 # 09 Y:1991 | 09 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,226 | $2,900 | Implemented |
OK0341 # 10 Y:1991 | 10 | 1991 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $26,053 | $16,500 | Implemented |
OK0343 # 01 Y:1991 | 01 | 1991 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $26,827 | $0 | Implemented |
OK0343 # 02 Y:1991 | 02 | 1991 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $17,827 | $31,500 | Implemented |
OK0343 # 03 Y:1991 | 03 | 1991 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $14,906 | $0 | Implemented |
OK0343 # 04 Y:1991 | 04 | 1991 | OPTIMIZE PLANT POWER FACTOR | $1,994 | $4,536 | Implemented |
OK0343 # 05 Y:1991 | 05 | 1991 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,024 | $0 | Implemented |
OK0343 # 06 Y:1991 | 06 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $916 | $0 | Implemented |
OK0343 # 07 Y:1991 | 07 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $581 | $1,634 | Implemented |