Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,708
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0239 # 01 Y:2002 | 01 | 2002 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $4,912 | $0 | Not Implemented |
SF0239 # 02 Y:2002 | 02 | 2002 | INTERLOCK HEATING AND AIR CONDITIONING SYSTEMS TO PREVENT SIMULTANEOUS OPERATION | $8,588 | $460 | Not Implemented |
SF0239 # 03 Y:2002 | 03 | 2002 | REDUCE FLUID FLOW RATES | $34,956 | $25,339 | Not Implemented |
SF0239 # 04 Y:2002 | 04 | 2002 | INSTALL OCCUPANCY SENSORS | $324 | $480 | Not Implemented |
SF0239 # 05 Y:2002 | 05 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,127 | $33,923 | Not Implemented |
SF0239 # 06 Y:2002 | 06 | 2002 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $20,800 | $0 | Not Implemented |
WI0426 # 01 Y:2002 | 01 | 2002 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $4,113 | $0 | Not Implemented |
WI0426 # 02 Y:2002 | 02 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,187 | $8,714 | Implemented |
WI0426 # 03 Y:2002 | 03 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,916 | $150 | Implemented |
WI0426 # 04 Y:2002 | 04 | 2002 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,333 | $0 | Implemented |
WI0426 # 05 Y:2002 | 05 | 2002 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $797 | $800 | Not Implemented |
WI0426 # 06 Y:2002 | 06 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $327 | $640 | Not Implemented |
WI0426 # 07 Y:2002 | 07 | 2002 | INSTALL OCCUPANCY SENSORS | $243 | $1,000 | Not Implemented |
LM0040 # 01 Y:2002 | 01 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,685 | $450 | Not Implemented |
LM0040 # 02 Y:2002 | 02 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,048 | $600 | Not Implemented |
LM0040 # 03 Y:2002 | 03 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,476 | $288 | Implemented |
LM0040 # 04 Y:2002 | 04 | 2002 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,360 | $1,440 | Not Implemented |
LM0040 # 05 Y:2002 | 05 | 2002 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,888 | $9,000 | Not Implemented |
LM0040 # 06 Y:2002 | 06 | 2002 | MAINTAIN CLEAN CONDITIONS BEFORE PAINTING | $108,300 | $200 | Not Implemented |
LM0040 # 07 Y:2002 | 07 | 2002 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $45,250 | $1,332 | Not Implemented |
LM0040 # 08 Y:2002 | 08 | 2002 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $13,000 | $3,900 | Not Implemented |
AS0329 # 01 Y:2002 | 01 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,200 | $13,655 | Not Implemented |
AS0329 # 02 Y:2002 | 02 | 2002 | INSTALL OCCUPANCY SENSORS | $615 | $1,500 | Not Implemented |
AS0329 # 03 Y:2002 | 03 | 2002 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $6,444 | $43,930 | Not Implemented |
AS0329 # 04 Y:2002 | 04 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $94 | $48 | Not Implemented |