Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Loyola Marymount University |
---|---|
Assessment Year | 2002 |
Principal Product | iron pipe fittings |
NAICS | n/a |
SIC | 3498 - Fabricated Pipe And Fittings |
Sales | $10,000,000-$50,000,000 |
# of Employees | 80 |
Plant Area (Sq.Ft.) | 90,440 |
Annual Production | 5,428,665 Pounds |
Production Hrs. Annual | 4,160 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $170,878 | 2,055,357 | kWh | $0.08 |
Electricity Demand | $69,859 | 8,748 | kW-months/year | $7.99 |
Electricity Fees | $25,327 | - | $ | - |
Natural Gas | $45,689 | 8,557 | MMBtu | $5.34 |
TOTAL ENERGY COSTS | $311,753 | |||
RECOMMENDED SAVINGS* | $180,007 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $1,476 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,685 Cost: $450 |
$2,855 | 27,000 | $610 | 78 | - | - | $(-780) | - | - | - | - | - |
$2,855 27,000 kWh |
$610 78 kW-months/year |
- - MMBtu |
$(-780) - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,048 Cost: $600 |
$1,484 | 14,040 | $564 | 72 | - | - | - | - | - | - | - | - |
$1,484 14,040 kWh |
$564 72 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,476 Cost: $288 |
$1,240 | 11,737 | $236 | 30 | - | - | - | - | - | - | - | - |
$1,240 11,737 kWh |
$236 30 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $2,360 Cost: $1,440 |
$1,586 | 15,004 | $774 | 98 | - | - | - | - | - | - | - | - |
$1,586 15,004 kWh |
$774 98 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $4,888 Cost: $9,000 |
- | - | - | - | $4,888 | 1,459 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$4,888 1,459 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.121 MAINTAIN CLEAN CONDITIONS BEFORE PAINTING |
Savings: $108,300 Cost: $200 |
- | - | - | - | - | - | - | - | $108,300 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$108,300 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.132 PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST |
Savings: $45,250 Cost: $1,332 |
- | - | - | - | - | - | - | - | - | - | $45,250 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
$45,250 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.513 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS |
Savings: $13,000 Cost: $3,900 |
- | - | - | - | - | - | $13,000 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$13,000 - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $180,007 Cost: $17,210 |
$7,165 | 67,781 | $2,184 | 278 | $4,888 | 1,459 | $12,220 | - | $108,300 | - | $45,250 | - | $7,165 67,781 kWh |
$2,184 278 kW-months/year |
$4,888 1,459 MMBtu |
$12,220 - $ |
$108,300 - $ |
$45,250 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $1,476 Cost: $288 |
$1,240 | 11,737 | $236 | 30 | - | - | - | - | - | - | - | - | $1,240 11,737 kWh |
$236 30 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost |