IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,380

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0136 # 01 Y:1989 01 1989 INSTALL SET-BACK TIMERS $422 $892 Implemented
MA0136 # 02 Y:1989 02 1989 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,244 $480 Not Implemented
MA0136 # 03 Y:1989 03 1989 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $1,017 $1,400 Implemented
MA0136 # 04 Y:1989 04 1989 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $372 $200 Not Implemented
MA0136 # 05 Y:1989 05 1989 RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS $2,595 $3,602 Not Implemented
MA0142 # 01 Y:1989 01 1989 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $16,859 $570 Implemented
MA0142 # 02 Y:1989 02 1989 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $39,982 $5,700 Not Implemented
MA0142 # 03 Y:1989 03 1989 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $42,075 $45,870 Not Implemented
MA0142 # 04 Y:1989 04 1989 INSTALL SET-BACK TIMERS $6,809 $900 Not Implemented
MA0142 # 05 Y:1989 05 1989 USE DIRECT AIR SUPPLY TO EXHAUST HOODS $43,200 $381,000 Not Implemented
MA0142 # 06 Y:1989 06 1989 UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING $27,100 $13,000 Implemented
MA0142 # 07 Y:1989 07 1989 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $52,700 $680 Implemented
OK0273 # 01 Y:1989 01 1989 INSTALL / REPAIR INSULATION ON STEAM LINES $343 $199 Not Implemented
OK0273 # 02 Y:1989 02 1989 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $339 $360 Not Implemented
OK0273 # 03 Y:1989 03 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $263 $0 Implemented
OK0273 # 04 Y:1989 04 1989 INSULATE BARE EQUIPMENT $110 $255 Not Implemented
OK0273 # 05 Y:1989 05 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $408 $126 Not Implemented
OK0273 # 06 Y:1989 06 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $233 $244 Not Implemented
OR0047 # 01 Y:1989 01 1989 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $8,348 $0 Implemented
OR0047 # 02 Y:1989 02 1989 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $5,777 $0 Implemented
OR0047 # 03 Y:1989 03 1989 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $3,193 $0 Implemented
OR0047 # 04 Y:1989 04 1989 INSTALL SET-BACK TIMERS $3,718 $0 Implemented
OR0047 # 05 Y:1989 05 1989 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,679 $500 Implemented
OR0047 # 06 Y:1989 06 1989 DIRECT WARMEST AIR TO COMBUSTION INTAKE $544 $650 Not Implemented
OR0047 # 07 Y:1989 07 1989 INSULATE FEEDWATER TANK $435 $658 Implemented