Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,304
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0574 # 09 Y:2010 | 09 | 2010 | INSULATE BARE EQUIPMENT | $240 | $185 | Not Implemented |
AM0574 # 10 Y:2010 | 10 | 2010 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $111 | $0 | Not Implemented |
UW0041 # 01 Y:2010 | 01 | 2010 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $1,098 | $866 | Implemented |
UW0041 # 02 Y:2010 | 02 | 2010 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $653 | $1,306 | Implemented |
UW0041 # 03 Y:2010 | 03 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $521 | $261 | Implemented |
SU0294 # 01 Y:2010 | 01 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,067 | $0 | Implemented |
SU0294 # 02 Y:2010 | 02 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,276 | $0 | Implemented |
SU0294 # 03 Y:2010 | 03 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,995 | $1,245 | Not Implemented |
SU0294 # 04 Y:2010 | 04 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,763 | $1,440 | Implemented |
SU0294 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $267 | $492 | Implemented |
SU0294 # 06 Y:2010 | 06 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $142 | $817 | Implemented |
SU0294 # 07 Y:2010 | 07 | 2010 | OPTIMIZE PLANT POWER FACTOR | $1,808 | $9,734 | Not Implemented |
SU0294 # 08 Y:2010 | 08 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,680 | $17,732 | Not Implemented |
SU0294 # 09 Y:2010 | 09 | 2010 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $108 | $516 | Not Implemented |
SU0294 # 10 Y:2010 | 10 | 2010 | UPGRADE OBSOLETE EQUIPMENT | $276 | $1,831 | Implemented |
OK0788 # 01 Y:2010 | 01 | 2010 | INSTALL / REPAIR INSULATION ON STEAM LINES | $285 | $451 | Implemented |
OK0788 # 02 Y:2010 | 02 | 2010 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $29,667 | $2,587 | Not Implemented |
OK0788 # 03 Y:2010 | 03 | 2010 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $1,568 | $1,078 | Not Implemented |
OK0788 # 04 Y:2010 | 04 | 2010 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $3,625 | $1,176 | Implemented |
OK0788 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,103 | $5,543 | Not Implemented |
OK0788 # 06 Y:2010 | 06 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,350 | $8,818 | Implemented |
OK0788 # 07 Y:2010 | 07 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $35,265 | $98,109 | Implemented |
OK0788 # 08 Y:2010 | 08 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $441 | $1,170 | Not Implemented |
OK0788 # 09 Y:2010 | 09 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,877 | $0 | Not Implemented |
OK0788 # 10 Y:2010 | 10 | 2010 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $15,837 | $12,000 | Implemented |