Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,597
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0544 # 04 Y:2017 | 04 | 2017 | RECYCLE WHITE WATER | $61,512 | $25,000 | Implemented |
WV0544 # 05 Y:2017 | 05 | 2017 | IMPROVE COMBUSTION CONTROL CAPABILITY | $50,032 | $125,526 | Not Implemented |
WV0544 # 06 Y:2017 | 06 | 2017 | INCREASE AMOUNT OF CONDENSATE RETURNED | $26,543 | $125,000 | Not Implemented |
WV0544 # 07 Y:2017 | 07 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $10,362 | $0 | Implemented |
WV0544 # 08 Y:2017 | 08 | 2017 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $10,299 | $1,000 | Implemented |
WV0544 # 09 Y:2017 | 09 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,346 | $25,467 | Not Implemented |
WV0544 # 10 Y:2017 | 10 | 2017 | DEVELOP A REPAIR/REPLACE POLICY | $4,065 | $1,108 | Implemented |
WV0544 # 11 Y:2017 | 11 | 2017 | UPGRADE CONTROLS ON COMPRESSORS | $3,967 | $15,395 | Not Implemented |
WV0544 # 12 Y:2017 | 12 | 2017 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,588 | $2,000 | Implemented |
WV0544 # 13 Y:2017 | 13 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,526 | $732 | Implemented |
WV0544 # 14 Y:2017 | 14 | 2017 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,358 | $3,438 | Not Implemented |
WV0544 # 15 Y:2017 | 15 | 2017 | INSULATE BARE EQUIPMENT | $268 | $876 | Not Implemented |
SF0501 # 01 Y:2017 | 01 | 2017 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $4,520 | $0 | Implemented |
SF0501 # 02 Y:2017 | 02 | 2017 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,047 | $0 | Not Implemented |
SF0501 # 03 Y:2017 | 03 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $777 | $84 | Not Implemented |
SF0501 # 04 Y:2017 | 04 | 2017 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $7,074 | $1,769 | Implemented |
SF0501 # 05 Y:2017 | 05 | 2017 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $2,356 | $1,821 | Not Implemented |
SF0501 # 06 Y:2017 | 06 | 2017 | USE SOLAR HEAT TO MAKE ELECTRICTY | $147,360 | $665,154 | Not Implemented |
UD0966 # 01 Y:2017 | 01 | 2017 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $217,648 | $48,962 | Not Implemented |
UD0966 # 02 Y:2017 | 02 | 2017 | INSTALL TIMERS AND/OR THERMOSTATS | $12,245 | $25,000 | Not Implemented |
UD0966 # 03 Y:2017 | 03 | 2017 | IMPROVE COMBUSTION CONTROL CAPABILITY | $270,579 | $100,000 | Not Implemented |
UD0966 # 04 Y:2017 | 04 | 2017 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $8,225 | $4,000 | Not Implemented |
UD0966 # 05 Y:2017 | 05 | 2017 | RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS | $57,432 | $35,000 | Not Implemented |
UD0966 # 06 Y:2017 | 06 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $14,748 | $4,000 | Not Implemented |
UD0966 # 07 Y:2017 | 07 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $383,642 | $613,600 | Implemented |