Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

54

matching recommendations
Reset
SIC 38 Instruments And Related Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0079 # 01 Y:1986 01 1986 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS $478 $350 Implemented
MA0079 # 02 Y:1986 02 1986 REPAIR OR REPLACE STEAM TRAPS $4,572 $600 Implemented
MA0079 # 05 Y:1986 05 1986 USE OPTIMUM THICKNESS INSULATION $21,098 $5,000 Implemented
MA0079 # 04 Y:1986 04 1986 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $6,519 $13,000 Not Implemented
MA0079 # 03 Y:1986 03 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,763 $4,700 Implemented
MA0076 # 02 Y:1986 02 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $526 $77 Implemented
MA0076 # 05 Y:1986 05 1986 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $882 $3,588 Implemented
MA0076 # 01 Y:1986 01 1986 USE DIRECT AIR SUPPLY TO EXHAUST HOODS $3,524 $6,000 Implemented
MA0076 # 03 Y:1986 03 1986 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $712 $2,050 Not Implemented
MA0076 # 06 Y:1986 06 1986 RECOVER AND REUSE COOLING WATER $1,226 $660 Not Implemented
MA0076 # 04 Y:1986 04 1986 RECOVER WASTE HEAT FROM EQUIPMENT $1,822 $1,100 Not Implemented
MA0076 # 07 Y:1986 07 1986 INSTALL STORM WINDOWS AND DOORS $432 $1,114 Not Implemented
MA0073 # 01 Y:1986 01 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,084 $500 Not Implemented
MA0073 # 02 Y:1986 02 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $141 $210 Not Implemented
MA0073 # 03 Y:1986 03 1986 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $4,124 $12,000 Not Implemented
AT0050 # 01 Y:1986 01 1986 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $859 $400 Implemented
AT0050 # 02 Y:1986 02 1986 UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING $6,892 $1,700 Not Implemented
AT0050 # 03 Y:1986 03 1986 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $14,822 $20,000 Not Implemented
AT0050 # 04 Y:1986 04 1986 RECOVER WASTE HEAT FROM EQUIPMENT $361 $300 Not Implemented
AT0050 # 05 Y:1986 05 1986 REDUCE VENTILATION AIR $8,542 $203 Not Implemented
KU0203 # 07 Y:1986 07 1986 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $730 $117 Implemented
KU0203 # 08 Y:1986 08 1986 INSTALL AUTOMATIC STACK DAMPER $303 $750 Implemented
KU0203 # 09 Y:1986 09 1986 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $285 $0 Implemented
KU0203 # 06 Y:1986 06 1986 USE DEMAND CONTROLLER OR LOAD SHEDDER $2,080 $1,500 Not Implemented
KU0203 # 05 Y:1986 05 1986 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $1,800 $300 Implemented