Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
25
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0171 # 06 Y:2000 | 06 | 2000 | IMPROVE SPACE COMFORT CONDITIONING | $64,866 | $23,339 | n/a |
MS0171 # 05 Y:2000 | 05 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,474 | $697 | n/a |
MS0171 # 04 Y:2000 | 04 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,198 | $228 | n/a |
MS0171 # 03 Y:2000 | 03 | 2000 | INSTALL TIMERS AND/OR THERMOSTATS | $1,243 | $827 | n/a |
MS0171 # 02 Y:2000 | 02 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $5,812 | $1,207 | n/a |
MS0171 # 01 Y:2000 | 01 | 2000 | INSULATE BARE EQUIPMENT | $162 | $364 | n/a |
GT0698 # 02 Y:2000 | 02 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $85,596 | $65,000 | Not Implemented |
GT0698 # 10 Y:2000 | 10 | 2000 | AVOID COOLING OF PROCESS STREAMS OR MATERIALS THAT MUST SUBSEQUENTLY BE HEATED | $18,139 | $77,275 | Not Implemented |
GT0698 # 08 Y:2000 | 08 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $29,275 | $55,000 | Not Implemented |
GT0698 # 01 Y:2000 | 01 | 2000 | INSULATE BARE EQUIPMENT | $7,360 | $3,240 | Implemented |
GT0698 # 03 Y:2000 | 03 | 2000 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,389 | $250 | Implemented |
GT0698 # 04 Y:2000 | 04 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $422 | $192 | Not Implemented |
GT0698 # 05 Y:2000 | 05 | 2000 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $108,000 | $160,000 | Not Implemented |
GT0698 # 06 Y:2000 | 06 | 2000 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $59,243 | $300,000 | Implemented |
GT0698 # 07 Y:2000 | 07 | 2000 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,235 | $1,800 | Implemented |
GT0698 # 09 Y:2000 | 09 | 2000 | FILTER AND REUSE HYDRAULIC OIL | $3,712 | $6,200 | Not Implemented |
MS0160 # 06 Y:2000 | 06 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $915 | $2,700 | Not Implemented |
MS0160 # 07 Y:2000 | 07 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,708 | $2,195 | Not Implemented |
MS0160 # 08 Y:2000 | 08 | 2000 | COMBINE UTILITY METERS | $3,023 | $1,000 | Not Implemented |
MS0160 # 09 Y:2000 | 09 | 2000 | BURN WASTE OIL FOR HEAT | $1,949 | $2,067 | Not Implemented |
MS0160 # 05 Y:2000 | 05 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $593 | $3,002 | Not Implemented |
MS0160 # 04 Y:2000 | 04 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,075 | $9,610 | Not Implemented |
MS0160 # 03 Y:2000 | 03 | 2000 | INSTALL TIMERS AND/OR THERMOSTATS | $469 | $472 | Not Implemented |
MS0160 # 02 Y:2000 | 02 | 2000 | USE SYNTHETIC LUBRICANT | $1,840 | $1,210 | Implemented |
MS0160 # 01 Y:2000 | 01 | 2000 | BURN A LESS EXPENSIVE GRADE OF FUEL | $2,113 | $710 | Not Implemented |