IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

245

matching recommendations
Reset
NAICS 336 Transportation Equipment Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LM0054 # 02 Y:2003 02 2003 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $5,770 $0 Implemented
LM0054 # 03 Y:2003 03 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,079 $410 Implemented
LM0054 # 04 Y:2003 04 2003 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,410 $1,000 Implemented
LM0054 # 05 Y:2003 05 2003 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $346 $0 Implemented
LM0054 # 06 Y:2003 06 2003 COVER OPEN TANKS $3,464 $420 Implemented
LM0054 # 07 Y:2003 07 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,472 $4,000 Not Implemented
LM0054 # 08 Y:2003 08 2003 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $316 $400 Implemented
SD0312 # 01 Y:2003 01 2003 USE PHOTOCELL CONTROLS $16,275 $11,000 Not Implemented
SD0312 # 02 Y:2003 02 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,368 $0 Not Implemented
SD0312 # 03 Y:2003 03 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,675 $400 Not Implemented
SD0312 # 04 Y:2003 04 2003 TURN OFF EQUIPMENT WHEN NOT IN USE $781 $0 Implemented
SD0312 # 05 Y:2003 05 2003 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $7,500 $10,000 Not Implemented
SF0242 # 01 Y:2002 01 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,642 $300 Implemented
SF0242 # 02 Y:2002 02 2002 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,176 $572 Implemented
SF0242 # 03 Y:2002 03 2002 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,518 $1,217 Implemented
SF0242 # 04 Y:2002 04 2002 RECOVER WASTE HEAT FROM EQUIPMENT $4,397 $3,036 Not Implemented
SF0242 # 05 Y:2002 05 2002 COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER $553 $1,000 Not Implemented
SF0242 # 06 Y:2002 06 2002 INSTALL / REPAIR INSULATION ON STEAM LINES $2,020 $3,067 Not Implemented
SF0242 # 07 Y:2002 07 2002 USE PHOTOCELL CONTROLS $433 $1,200 Not Implemented
SF0242 # 08 Y:2002 08 2002 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $16,216 $16,216 Not Implemented