Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

318

matching recommendations
Reset
SIC 36 Electronic & Other Electric Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SD0077 # 12 Y:1994 12 1994 INSTALL TIMERS AND/OR THERMOSTATS $411 $210 Implemented
SD0077 # 13 Y:1994 13 1994 INSTALL TIMERS AND/OR THERMOSTATS $8,853 $600 Implemented
SF0021 # 02 Y:1994 02 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,899 $5,951 Implemented
SD0074 # 01 Y:1994 01 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $5,284 $4,840 Implemented
SD0074 # 02 Y:1994 02 1994 RECOVER WASTE HEAT FROM EQUIPMENT $8,666 $4,290 Implemented
SD0074 # 03 Y:1994 03 1994 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $4,304 $900 Implemented
SD0074 # 05 Y:1994 05 1994 USE POWER DURING OFF-PEAK PERIODS $3,428 $0 Implemented
SD0074 # 10 Y:1994 10 1994 INSTALL SPECTRAL REFLECTORS / DELAMP $3,452 $2,820 Implemented
SD0074 # 11 Y:1994 11 1994 INSTALL OCCUPANCY SENSORS $1,727 $2,440 Implemented
SD0074 # 12 Y:1994 12 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $977 $924 Implemented
SD0074 # 13 Y:1994 13 1994 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $3,003 $240 Implemented
SD0074 # 14 Y:1994 14 1994 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $460 $100 Implemented
SD0074 # 15 Y:1994 15 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $575 $315 Implemented
SF0010 # 01 Y:1993 01 1993 USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM $2,532 $5,410 Implemented
SF0010 # 05 Y:1993 05 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,713 $9,277 Implemented
SF0010 # 06 Y:1993 06 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $8,002 $4,553 Implemented
SD0061 # 01 Y:1993 01 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $648 $827 Implemented
SD0061 # 02 Y:1993 02 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,078 $100 Implemented
SD0061 # 04 Y:1993 04 1993 COVER OPEN TANKS $5,954 $284 Implemented
SD0061 # 05 Y:1993 05 1993 INSULATE BARE EQUIPMENT $1,375 $85 Implemented
SD0061 # 11 Y:1993 11 1993 USE PHOTOCELL CONTROLS $6,945 $4,000 Implemented
SD0025 # 01 Y:1992 01 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $130 $900 Implemented
SD0025 # 02 Y:1992 02 1992 TURN OFF EQUIPMENT WHEN NOT IN USE $710 $120 Implemented
SD0025 # 03 Y:1992 03 1992 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $16,866 $2,000 Implemented
SD0025 # 05 Y:1992 05 1992 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $4,093 $4,450 Implemented